IAQ report, 201 Warren Street, Feb 2002

Machine-extracted title · confidence 55%

Indoor air quality measurements collected mid-February 2002 for a NYC school.

NYC-WTC_000327434–000327437
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan Indoor Air Quality Assessment i Pages P. S. 89M ATC ProiectNo: 15-19125-0297

The assessment was perfoimed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were mherent limitations created by constraints of time, operational and work practice variability, variations in indoor air quality parameters and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUATION CRITERIA

Currently, there are no regulatory' standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

Ventilation for Acceptable Indoor Air Quality (ASHIL4£ 62-1 PP9f, America.n Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); f Thennal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

TABLET ■ i TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EV ALUATED 1 ________________ Carbon Dioxide ____ ___________ ! <700 parts per million (ppm) ASHRAE 62 ■Mk (CQ2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) 65 micrograms per cubic meter .USEPA,;NPAAQS. , Respirable of air (p.g/m3) 24-hour average Particulates (PM2.5) 40 pig/m^ 24-hour average USEPA - recommendation for children/sensitive individuals Temperature Summer; 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30-60 % ASHRAE 35 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American IndusUiaPHygiene Association

CITY_21MC1OO_OO327O9OO

NYC-WTC_000327435

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000327435Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →