NYC-WTC_000400206
IAQ measurements report for PS 89M, March 13, 2002, ATC.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC IAQ measurements at PS 89M, March 13, 2002, for NYC BOE.
NYC-WTC_000326812–000326815OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 14,2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Project No. 15-19125-0297
Real-Time Ewvikommental Measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:10 A.M. and concluded at approximately 11:30 A.M.
Temperature
Indoor dry bulb temperature measurements ranged from 71.6 °F to 76.5 °F. Seven (7) of the measurements were above and sixty-three (63) were within the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the heating season (wintertime eonditions). The outdoor temperature measurements ranged from 43.8 to 45.6 °F.
Relative Humidity
The relative humidity indoors ranged from 25.5 to 33.7 percent. Fifty (50) of the indoor measurements for relative humidity were below and twenty (20) were within the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 43 .0 to 47.3 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 496 ppm to 945 ppm. All of the CO2 indoor measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 470 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1170 ppm (background level A- 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was also 0 ppm for all collected readings.
Respirable Particulates (PM2 §)
Respirable particulate concentrations* indoors ranged between 14 pg/m3 to 35 pg/m3. All of the measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PMg.5 concentration for the entire school building was approximately 24 pg/m3. The PMg.s average concentration was below the USEPA recommended concentration' of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged
CITY_21MC100_005390437
NYC-WTC_000326814
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000400206
IAQ measurements report for PS 89M, March 13, 2002, ATC.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274771
ATC IAQ measurements collected March 12, 2002 at PS 89M for BOE.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383828
Indoor air quality measurements collected March 12, 2002 at PS89M for BOE evaluation.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313327
ATC report of IAQ measurements conducted at PS 89M.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383840
ATC report of IAQ measurements at PS 89M, BOE-requested evaluation of air quality.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313390
ATC IAQ measurements at P.S. 89M; measurements on March 21, 2002 for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313475
IAQ measurements collected for PS 89M; BOE-requested evaluation, April 16-17, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382647
ATC memo detailing scope of indoor air quality evaluation at PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328214
Indoor air quality measurements report for P.S.89M, April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392637
ATC IAQ measurements report dated April 17, 2002; school air quality evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313344
IAQ findings and scope of work for PS 89M indoor environment.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394421
Indoor air quality report for P.S. 89M with April 16, 2002 measurements.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000202327
Report from ATC Associates detailing indoor air quality measurements collected at a New York City Board of Education school to evaluate building conditions.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328280
Indoor air quality measurements collected on multiple dates for PS 89M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400206
IAQ measurements report for PS 89M, March 13, 2002, ATC.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274759
ATC report of IAQ measurements collected March 11, 2002 at PS 89M for BOE.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392608
ATC IAQ measurements report for April 11, 2002; school building air quality evaluation.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375521
IAQ measurements at PS 150M prior to re-occupancy, March 12, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000400206
IAQ measurements report for PS 89M, March 13, 2002, ATC.
Similar indexed content
NYC-WTC_000274771
ATC IAQ measurements collected March 12, 2002 at PS 89M for BOE.
Similar indexed content
NYC-WTC_000383828
Indoor air quality measurements collected March 12, 2002 at PS89M for BOE evaluation.
Similar indexed content
NYC-WTC_000313327
ATC report of IAQ measurements conducted at PS 89M.
Similar indexed content
NYC-WTC_000383840
ATC report of IAQ measurements at PS 89M, BOE-requested evaluation of air quality.
Similar indexed content