TEM Asbestos (air) Count Sheet Client Name: m^C BOE Volume (liters): 1840 - Lab Group #: 7597 Filter Type / Filter Area: MCE 385 Lab Sample #: 4 Grid Opening Size: 0.01124' Client Sample #: 04 , Area Examined: 0.04496 mm-

GRID BOX: Magnification: 20,000 GRIDID; Accelerating Voltage: 100 KeV # Grid Openings: 4 Analysis Date: 5/1/02

Analysis Performed Bv: ROMAN PEYSAKHOV

GO. Structure Structure Type Length ID of Structure nTotK/ EDS No (Noradb F B C M >=5p Chrys Amphibole Nonasb Ambig/ND Elements) No Coord ■ ' —■ <5tJ

zp A '7^-------

I Struct = > O..5p > 5:1 Aspect Ratio Grid acceptance: V= Positive diffraction pattern properties conforming to undissolved filter, overlaoped or folded Totals laboratory identification criteria observed <10% particulate coverage >50% coverage ate

0= EDS spectrum conforming to laboratory least 20 unfolded or overlapped grid squares <5% F B C \: TT holes or opaque areas identification criteria observed Chrysotile AMPHIBOLES i Amphibole F = Single Fiber Amosite 8 = Bundle (<3 libers <1 fiber diameter apart Crocidolite Ambiguous C = Cluster (>3 intersections) Anthophyllite Non-Asbestos Tremolite M = Matrix Actinolite Non-Identified NSD = No Structures Detected

NYC-WTC_000324644

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324644Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →