Ambient air protocol, PS 89 Manhattan, 2002

Machine-extracted title · confidence 64%

Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ plan.

NYC-WTC_000324167–000324175
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLNG PROTOCOL for PS/IS89M. Page 9 of 9

HEAVY METAL AIR SAMPLES

• First floor hallway, outside cafeteria - one sample. • Inside playground, north side - one sample. • Inside playground south side - one sample. • Fifth floor roof - one sample.

All sample collected shall be analyzed utilizing NIOSH 7300 method for Al, Cd, Or, Co, Cu, Fe, Mg, Mn, Mo, Ni, Zn and NIOSH 6009 method for Hg.

Results from samples collected shall be reported to BOE, LIFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactory ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.

TVOCs AIR SAMPLES

• First floor hallway, outside cafeteria - one sample. • Inside playground, north side - one sample. • Inside playground south side - one sample. • Fifth floor roof - one sample.

All sample collected shall be analyzed utilizing Hydrocarbon Scan (16+A&B) OSHA 7 method.

Results from samples collected shall be reported to BOE, UFT. School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactory ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.

NOTE: Please note that this protocol established to address the environmental concerns due to the WTC tragedy. Therefore, this document will be constantly reviewed and modified as the environmental conditions in Lower Manhattan are changing.

CITY_21MC100_003267217

NYC-WTC_000324175

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324175Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →