AMBIENT AIR AND DUSTSAMPUNG PROTOCOL for PS/IS39M. Page 6 of 9
• Classroom with south side unit ventilators - one sample immediately after the last class.
• First floor (Throughout) - Additional minimum of five (5) samples within classrooms where
present. One sample shall be collected within every Pre-K and Kindergarten classroom
where present.
• Second floor Hallways south end - one sample immediately after the last class.
• Second floor Classrooms - Additional minimum of five (5) samples within classrooms
where present One sample shall be collected within every Pre-K and Kindergarten
classroom where present.
• Third floor Classrooms - Additional minimum of five (5) samples within classrooms where
present. One sample shall be collected within every Pre-K and Kindergarten classroom
where present.
• Fourth floor Hallways south end - one sample immediately after the last class.
Fourth Floor Classrooms - Additional minimum of five (5) samples within classrooms
where present. One sample shall be collected within every Pre-K and Kindergarten
classroom where present.
• Outside Playground - three samples on playground surface after last class.
• Exterior Building Entrances - one sample on ground at exterior of north and south
entrances to the school.
All dust wipe samples taken shall be analyzed in accordance with EPA7082 method via
Flame Atomic Absorption (FAA).
Dust wipe results shall be considered satisfactory when the levels obtained are below the
EPA new levels for clearing a work area for re-occupancy after an EPA defined lead
abatement is performed, as specified in 40 CFR §745.227(eX8)(viii).
Floors: 40 micrograms of lead per square foot
Window Sills: 250 micrograms of lead per square foot
Exterior Concrete
or Rough Surfaces: 800 micrograms of lead per square foot
Dust wipe results shall be considered unsatisfactory when the levels obtained are greater
than the EPA new levels for clearing a work area for re-occupancy after an EPA defined lead
abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).
Floors: 40 micrograms of lead per square foot
Window Sills: 250 micrograms of lead per square foot
Exterior Concrete
or Rough Surfaces: 800 micrograms of lead per square foot
♦
Results from samples collected shall be reported to BOE, UFT, School Principal and the PA
consultant within 24 hours.