NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Ambient air and dust sampling protocol for PS 150 in Manhattan.
NYC-WTC_000324143–000324150OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
AMBIENT AIR AND DUST SAMPUNG PROTOCOL for PS150M Page 3 of 8
TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED
Temperature (T) Summer 73-79T at 50% RH ASHRAE 55 Winter: 68-75° F at 50% RH Relative Humidity (RH) 30-60% ASHRAE 55 Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAE 62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62) Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PMzs) meter of air (pg/m^)
USEPA = United Slates Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association ASHRAE = American Society of Heating. Refrigerating, and Air-Condilioning Engineers
Results from samples collected each day shall be reported verbally, no later than Sam the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. J In the event that real-time measurements of Temperature, Relative Humidity, and/or CO2 exceed the Cited Target Guidelines, ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.
The following actions are to be taken:
1. Building engineering controls shall be adjusted and/or implemented to improve conditions. In the event, that real-time measurements of respirable particulates exceed the cited Target Guidelines, ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.
In the event, that CO inside the school measured above the cited Target Guidelines (9ppm), ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.
CITY_21MC100_003267187
NYC-WTC_000324145
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
15 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324203
Ambient air and dust sampling protocol for PS 234; asbestos-monitoring.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324167
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ plan.
15 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324211
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324176
Ambient air and dust sampling protocol for PS 89 Manhattan, asbestos monitoring.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385851
Draft ambient air sampling protocol for PS 150 Manhattan with lAQ considerations.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385841
Ambient air and dust sampling protocol for PS 150 Manhattan after WTC events.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000385851
Draft ambient air sampling protocol for PS 150 Manhattan with lAQ considerations.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324203
Ambient air and dust sampling protocol for PS 234; asbestos-monitoring.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385841
Ambient air and dust sampling protocol for PS 150 Manhattan after WTC events.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385787
Ambient air sampling protocol for PS 234 with daily inside/outside tests.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
Similar indexed content
NYC-WTC_000385851
Draft ambient air sampling protocol for PS 150 Manhattan with lAQ considerations.
Similar indexed content
NYC-WTC_000385841
Ambient air and dust sampling protocol for PS 150 Manhattan after WTC events.
Similar indexed content
NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
Similar indexed content
NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
Similar indexed content