NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Asbestos TEM analysis; SAED/EDS identification for PS 130M site, throughout the school building, Oct 2001.
NYC-WTC_000324084OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM; With Fiber Identification by Selected-Area Electron Diffraction (SASD) and Energy-Dispersive X-RAY gpectroscopy (EDS) Method; AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1967
Sample Identification Analysis Parameters
Proj ect/Si ISOM, 143 Baxter St., NY, NY TEM Sample No.: 5726 61680 Throughout the School Building Date Received: 10/x8/01 Grid Openings Analyzed:_ 4
Project Sample No.: 25 Average Grid Opening: 106.00 urn
Air Volume :ie9 9 jrrerE Total Area Analyzed-. 0.0450 mmz
Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity:^22;2 s2mn^ Effective Area: 355 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Mumper Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct /iTinil ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes .ambiguou.s structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification fl 0 n 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0’000 N/A The estimated uncertainty ot tnis analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected ij Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
.nalyzed, by: Report Reviewed by:
Michael A. Goryoki, Ph.D. Michael A. Gorychi, Ph.D. Director of Eleccron Microscopy
|i
CITY_21MC100_011274429
NYC-WTC_000324084
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329870
TEM asbestos analysis; SAED/EDS; P.S. 130M; 10/18/01.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411526
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262767
TEM asbestos fiber analysis at PS 234M, includes SAED/EDS methods, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411525
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329871
TEM asbestos analysis; SAED/EDS; PS 110M project/site; 10/18/01.
7 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329855
TEM asbestos analysis data for PS 130M school building.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329870
TEM asbestos analysis; SAED/EDS; P.S. 130M; 10/18/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similar indexed content
NYC-WTC_000329868
TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
Similar indexed content
NYC-WTC_000329870
TEM asbestos analysis; SAED/EDS; P.S. 130M; 10/18/01.
Similar indexed content
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similar indexed content
NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
Similar indexed content