Asbestos TEM analysis, H.S. basement, Oct 2001

Machine-extracted title · confidence 42%

Asbestos fiber analysis by TEM for [site] H.S. basement and floors, Oct 2001.

NYC-WTC_000323959
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED WLA? Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/10/01

ASBESTOS FIBER AIsTALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Dr -action (SAID) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR. Part 763). Vd. 62, No, 210, October 30, 1987

Sample Idencification Analysis Paramecsrs

Project/Sits:'-Murrv Sergtraum H.S., 411 Pearl St., NY, NY TEM Samole No.: 5650 60703 Basement & Flcors 1-6 Dace Reesived:,10■39/01 Grid Openings Analysed:__ 4

Project Sample No. : i4BHS-B>6-10/9-ll Average Grid Opening: 106 . OO uni

Air Volume: Total Area Analysed:

Filter Type: MCE 25 mm diam.. Pore Size: 0,45 um Analytical Sensitivity: s/iiun2 Effective Ares: 3S5 mm2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZBD Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filler Air il ■“iber.q Bundles Clusters Struct >»5um Struct/mm2 Struct/ ncm/m3

Chrysotile Asbestos 0 0 c 0 0 0 0.0 0. 3000 c

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . oooo c Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestcs 0 0 0 0 0 0 0.0 0 . oooo N/A No Identi ilea tier. u 0 0 0 0 0.0 0.oooo N/A

Totals (All .Structures)' 0 C ■J . 0 0. OCOO N/A Tne estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Ma ]< Pevsakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3266949

NYC-WTC_000323959

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000323959Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →