NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

Indoor air quality report, M520 HS, Nov 2001

Machine-extracted title · confidence 42%

ATC Associates indoor air quality assessment at a New York City school on Nov 15, 2001.

NYC-WTC_000323908–000323913
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

.Mr. Bernard I’. Oriaii November I 5. 2001 ■ Indoor Air (Jnaliix .Assessment Page 3 SiLiwesant I licit School ( M477i .ATCProjeei_NtL_ 1^-19125-()24()

Real-Time iko^mem al Measurements

A fC collected sixty (60) sets of real-time environmental measurements consisting of (59) in the school building and one (I) outdoors. All seven Hoors of the school were surveyed. These results are described below. Field data sheets are found in Attachment I. Readings began at 12:00 P.M. and concluded after 3:00 P.M.

Temperature

Indoor dry bulb temperature measurements ranged from 73.1 °F to 77.6 °F. Forty-four (44) measurements were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASI IRAE Standard 55-1992 during the heating season (wintertime conditions). These measurements were collected throughout the school building. The outdoor temperature was 67.5 °F.

Relative Humidiiv

The relative humidity indoors ranged from 30.3 percent to 37.6 percent. All measurements were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity was 39.9 percent.

Carhem Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 534 ppm to 980 ppm. All COn measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO? concentration was 486 ppm. Therefore, the maximum acceptable level of COp at this location was 1186 ppm (background level -I- 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of COp indoors is occupant respiration.

C 'cirhon Monoxide Concentration

Carbon monoxide concentrations indoors were 1 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. l lie outdoor CO concentration was 1-2 ppm.

Respirable Particii/atex (PMp^j)

Respirable particulate concentrations* indoors ranged between 42 jug/mJ to 100 gg/m^ with an average of approximately 83 gg/m-*. Only five (5) measurements were below the NPAAQS of 65 gg/m^ 24-hoiir average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The outdoor respirable particulate concentrations were 103 gg/m^.

* The measurements made during this assessment were instantaneous readings, the guidelines are adopted from 24-hour and annual averages.

CITY_21MC100_003266812

NYC-WTC_000323910

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000323910Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →