H ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
n Tel. 212-353-8280
Fax 212-353-8306
r
u REPORT DATE: 08-12-02
n CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers Street, NY
PROJECT NUMBER: M477-15217-29881
SAMPLED BY: Client
J
SAMPLE DATE: 08-10-02
DATE RECEIVED: 08-10-02
DATE ANALYZED: 08-10-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(gg/fl?) (pg/ft*)
LW-01 21058 Sth Floor Roof MERHVAC #11 Louver 12.6 9.0
LW-02 21058 Sth Floor Roof MER HVAC #11 Liner <9.0 9.0
FB-1 21058 Field Blank <9.0 pg 9.0 pg
FB-2 21058 Field Blank <9.0 pg 9.0 pg
NOTE 1:
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 pg/fP, Window sills 250 pg/fF,
Window wells 400 pg/fd, Exterior surfaces 800 pg/fF.
NOTE 3:
Blank units are in pg
CERTIFICATION AND SIGNATURES
ANALYSIS PERFORMED BY: IL
REPORT PREPARED BY:
bi ATC certifies that this report is an accurate and authentic report of results obtained from the laboratory analysis.
QUALITY ASSURANCE COORDINATOR:
B LABORATORY DIRECTOR:
3 ATC is accredited by the New York State Department of Health Environmental Laboratory Approval Program (ELAP) and by the American
Industrial Hygiene Association (AMA) to perform analysis of lead in paint, dust wipes, air and soil samples. (ELAP #10879), (AMA #100229).