NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
fl Tel. 212-353-8280
Fax 212-353-8306
j REPORT DATE: 08-05-02
31 CLIENT: Taylor Environmental Group, Inc.
if
PROJECT NAME: SCA/Stuyvesant HS
1 345 Chambers Street, NY
PROJECT NUMBER: M477-15217/29881
SAMPLED BY: Client
SAMPLE DATE: 08-04-02
DATE RECEIVED: 08-04-02
DATE ANALYZED: 08-04-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(Pg/tf) (pg/f^)
LW-01 20903 Sth Floor HVAC (638) Corridor Supply West <9.0 9.0
O/S Rm 638
LW-02 20903 6th Floor HVAC Corridor Supply O/C C627 <9.0 9.0
LW-03 20903 6th Floor HVAC Corridor Supply East O/S East <9.0 9.0
Stair
LW-04 20903 6th Floor HVAC Corridor Return 0/0 Library 17.2 9.0
FBL-1 20903 Field Blank <9.0 ng 9.0 pg
FBL-2 20903 Field Blank <9.0 pg 9.0 pg
a
ii NOTEl:
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 Window sills 250 pg/fF,
ii Window wells 400 pg/fF, Exterior surfaces 800 pg/fF.
NOTE 3:
Blank units are in pg
n