NYC 9/11 Public Portal Document
91 ATC ASSOCIATES, INC
J 104 E 25th Street, 10th Floor
New York, NY 10010
fl Tel. 212-353-8280
Fax 212-353-8306
n
PS REPORT DATE; 07-30-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers Street, NY
PROJECT NUMBER: M477-15217/29881
SAMPLED BY: Client
SAMPLEDATE: 07-30-02
DATE RECEIVED: 07-30-02
DATE ANALYZED: 07-30-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
1^
iJ LW-07 20770 8th Floor Corridor East Supply Adj. 807 <9.0 9.0
LW-08 20770 Sth Floor Corridor Return Adj. to C821 26.7 9.0
Li
LW-09 20770 Sth Floor Corridor Supply (West) @ C832 23.5 9.0
LW-10 20770 Sth Floor Corridor West Supply @ 840 145.7
I, LW-11 20770 Field Blank <9.0 pg
9.0
9.0 pg
LW-12 20770 Field Blank <9.0 pg 9.0 pg
ti
NOTE I;
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2;
HUD Guidelines for final clearance dust wipe samples: Floor 40 pg/fF, Window sills 250 pg/fF,
Window wells 400 pg/fF, Exterior surfaces 800 pg/fF.
NOTE 3:
Blank units are in pg
CITY_21MC100_011273892
NYC-WTC_000323546