NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Cough and bronchial responsiveness in firefighters

Machine-extracted title · confidence 45%

Medical study abstract on FDNY exposure and bronchial reactivity.

NYC-WTC_000321824–000321833
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

COUGH AND BRONCHIAL RESPONSIVENESS IN FIREFIGHTERS AT THE WORLD TRADE CENTER

ertional dyspnea occurred in 95 percent. Upper-airway Lung Function symptoms, including nasal congestion, nasal drip, and Spiromctric values obtained before and atter the col­ sore throat, were reported by up to 82 percent (Ta­ lapse of the World Trade Center are shown in Table 2. ble 1). Overall, 87 percent had new or worsening FVC and FEV, values were less than 65 percent of symptoms of gastroesophageal reflux disease, which the predicted values in 1 percent of firefighters before were judged by most to be severe (Table 1). The in­ the collapse of the World Trade Center and in 12 per­ cidence of symptoms was not significantly different cent and 14 percent, respectively, after the collapse. among the four exposure groups. There were significant declines in FVC (P<0.01), The use of respiratory protection was not associ­ FEVi (P<0.01), and the maximal forced expiratory ated with a significandy decreased risk of lower-airway flow between expired volumes of 25 percent and 75 symptoms, decreased pulmonary function, or airway percent of vital capacity (P<0.01). The magnitude of hyperreactivity. However, respirators were worn rarely the reductions in FVC and FEV, was nearly equal, or not at all by 93 percent of firefighters on the day with declines of at least 0.5 liter in 58 percent and of the collapse, by 85 percent on the day after the 54 percent of firefighters, respectively. There were no collapse, and by 76 percent on the second through significant differences in spirometric values or the mag­ sixth days after the collapse. Even when respirators nitude of declines among the four exposure groups, were used, the most common type was a simple pa- but die declines tended to be least in the group with per dust mask rather than a fitted respirator certified I the lowest level of exposure. by the National Institute of Occupational Safety and Lung volumes and carbon monoxide diffusing ca­ Health (self contained breathing apparatus, N95, or pacity were within normal limits in 108 firefighters dual-cartridge half face P-100 respirator). By week 2, with World Trade Center cough who were tested. 65 percent of firefighters with World Trade Center There were no significant differences in values between cough reported frequent use of respirators, and 71 per­ firefighters with abnormal findings on chest radiog­ cent of those who so did used P-100 respirators. raphy and those with normal findings. Sixty-two per-

Table 2. Spirometric Valves in Firi^figiiters with Wori.d TRaWe Center (WTC) Cough, According to the Level of E.xposure to Kespirvlory Irritants at the Site.*

Age-Adjusted Variable Before Collapse of WTCt After Collapse of WTC Decrease I.H ERS V. UP PBEniCTKIt I ITl-Rs % nr pRFnic.TFn i.nTR.'i

mean ±SD (range)

FVC High level of exposure 4.64*0.82 92±U (70-120) 4.11±0.92$ 81*15 (45-108)$ -0.62=0.78 Moderate level of exposure 4 86 = 0.93 95=15(45-143) 4.25 = 0.80$ 83 = 15 (41-126)$ -0.73 = 0.76 Low level of e.xposure 492 = 0.54 98=9 (83-107) 4.19 = 0.57$ 83=10 (72-105)$ -0.40 = 0.59 FEV, High level of exposure 3.95*0.71 95-13(72-126) 3.432.0.75$ 82rl6 (35-110)$ -0.56-0.70 Moderate level of exposure 4.05±0.76 96rl4 (46-143) 3.48±0,71$ 83-16 (39-128)$ -0.64-0.69 Low level of exposure 4.08-0.52 99-12(80-114) 3.46±0.47$ 84-11 (68-103)$ -0.37-0 43 FEVpFVC High level of exposure 0.85±0.05 0,83±0.08 Moderate level of exposure 0.84±0.06 0.82±0.08 Low level of exposure 0.83±0.05 0.83±0.07

High level of exposure 3.96±0.93 88±17 (62-120) 3.27±117$ 77*17 (19-107) Moderate level of exposure 3.88±0.94 87*17 (42-121) 3.22*0.94$ 74*15 (30-103)$ Low level of exposure 3.47*0.57 81*15 (66-105) 3.05±0.83 73*18 (39-95)

‘Levels of exposure are defined in Figure 1. FVC denotes forced viral capacity, FEV, forced expiratory volume in one second, and FEF-^_75,^ rhe ma.ximaJ forced expiratory flow between expired volumes of 25 and 75 percent of the vital capacity. tValues were obtained one to two years before the collapse of the World Trade Center. tP<0.01 by analysis of variance for the comparison with the value obtained before the collapse of the World Trade Center. §P = 0.03 by analysis of variance for the comparison with the value obtained before the collapse of the World Trade Center.

N Engl J Med, Vol. 347, No. 11 • September 12, 2002 • www.nejm.org • 811

CITY__21MC10 0_0 06 7416 74

NYC-WTC_000321829

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321829Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →