To: Teachers, Students and Staff of Stuyvesant H.S ASSOCIATES INC-

From: Michael Parpounas, Vice President - ATC CO: Bernard Orlan, Director E.H.S. - BOE Date; 10/12/01 Re: Monitoring at Stuyvesant High School

Page 2 of 5

• Each morning, results from samples collected the previous day are reported verbally and/or sent via fax to BOE, UFT, School Principal and the PA consultant. In the event that unsatisfactory results (>70 s/mm^) are obtained, they will be reported immediately.

INDOR AIR QUALITY

To address lAQ concerns, each day from Monday through Friday, ATC performs the following:

• A visual inspection to assess conditions present in the school at the time of the site visit.

• Collect real-time environmental measurements, at various locations throughout the school, of temperature, relative humidity, carbon dioxide (CO?), carbon monoxide (CO), total volatile organic compounds (TVOCs) and respirable particulates.

ATC measures temperature, relative humidity, CO2 and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.

ATC measures concentrations of respirable particulates with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.

ATC measures concentrations of TVOCs using a RAE Systems, Inc. MiniRAE® photoionization detector (PID).

EVALUATION CRITERIA: Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

The table below lists target guidelines for the parameters that ATC evaluates during these investigations at Stuyvesant H.S.

CITY_21MC100_003036288

NYC-WTC_000321455

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321455Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000256164

Indoor air quality measurements conducted at Stuyvesant High School.

Similar indexed content

NYC-WTC_000256013

ATC memo accompanying IAQ report for Stuyvesant High School, February 12, 2002.

Similar indexed content

Compare copies and versions →