NYC 9/11 Public Portal Document
[jessica Leighton - RA_sitrepO2-26.wpd Pages]
NYC / ER (Feb 15) - Particulate Monitoring (TEOM PM,o)
o Wall Street - 24-hour average concentrations for this period was 24.41 ug/m\
o All readings below the National Ambient Air Quality Standard for PMio (150
ug/m’).
NYC / ER (Feb 16) - Particulate Monitoring (TEOM PM;-)
o Park Row (Site 1) - 24-hr average concentration for this period was 15.86
ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period
was 17.33 ug/m^.
o Wall Street - 24-hour average concentrations for this period was 14.93 ug/m\
o All readings below the National Ambient Air Quality Standard for PM2 5 (65
ug/m’).
NYC / ER (Feb 16) - Particulate Monitoring (TEOM PMio)
o Wall Street - 24-hour average concentrations for this period was 24.57 ug/m\
o All readings below the National Ambient Air Quality Standard for PMio (150
ug/m^).
NYC / ER (Feb 17) - Particulate Monitoring (TEOM PM 2.5)
o Park Row (Site 1) - 24-hr average concentration for this period was 7.85
ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period
was 10.00 ug/m\
o Wall Street - 24-hour average concentrations for this period was 9.14 ug/m\
o All readings below the National Ambient Air Quality Standard for PM2.5 (65
ug/m’).
NYC / ER (Feb 17) - Particulate Monitoring (TEOM PM 10)
o Wall Street - 24-hour average concentrations for this period was 19.13 ug/m\
o All readings below the National Ambient Air Quality Standard for PMio (150
ug/m^).
NYC / ER (Feb 25) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, and R) were below
the OSHA TWA.
o Instruments operated approximately 8!6 hours.
CITY_21MC100_000938737
NYC-WTC_000321355