NYC / ER (Feb 8) - Dioxin
o All 10 samples collected were below the EPA Removal Action level guideline
(based on a 30-year exposure).
o Note: Dioxin is not present in these air samples at levels sufficiently above
those in the control samples to be considered a valid result.
NYC/ER (Jan 15)-Metals
o 8 samples collected.
o 2 samples (Locations D and P) were not collected due to pumps being knocked
over from high winds.
o All metals were either not detected or were below applicable EPA Removal
Action level guidelines, OSHA PELs, and the NAAQS for lead.
o Note: Elevated levels of chromium identified in the quality control (QC)
samples (blanks) indicate that chromium is not present in these air samples at
levels sufficiently above those in the control samples to be considered a valid
result.
NYC / ER (Feb 9) - Particulate Monitoring (TEOM PM 2.5)
o Park Row (Site 1) - 24-hr average concentration for this period was 10.26
ug/m^.
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period
was 12.24 ug/m^.
o Wall Street - 24-hour average concentrations for this period was 11.22 ug/m\
o All readings below the National Ambient Air Quality Standard for PM2.5 (65
ug/m’).
NYC / ER (Feb 9) - Particulate Monitoring (TEOM PMio)
o Wall Street - 24-hour average concentrations for this period was 20.61 ug/nt^.
o All readings below the National Ambient Air Quality Standard for PMio (150
ug/m’).
NYC / ER (Feb 10) - Particulate Monitoring (TEOM PM 2.5)
o ParkRow (Site 1) - 24-hr average concentration for this period was 7.07
ug/m^.
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period