i Jessica Leighton - RA_sitrepO1-18.wpd Page 2 1
o Station N values ranged from 0.0 to 95.7 ug/m’ with an average of 37.5 ug/m\
a. Station R values ranged from 0.3 to 234.1 ug/m’ with an average of 39.0 ug/m\
NYC / ER (Jan 15) - Volatile Organics (Mobile Laboratory)
o Errata: Previously reported on the cover page of the January 16 Sampling Situation
Report that the Volatile Organics (Mobile Laboratory) presented on that day were
from January 12. The results posted in that report were actually from January 15.
NYC / ER (Jan 17) - Volatile Organics (Mobile Laboratory)
o Benzene was not detected above the detection limit (20 ppbv) in any of the four
samples collected (Washing Tent, Austin Tobin Plaza, North Tower, and South
Tower), including in the debris area at ground level.
o A limited number of VOCs were detected above the detection limit (20 ppbv) in only
the North and South Tower ground level samples.
Direct Reading Instruments
NYC / ER (Jan 17)
o Nothing of significance reported.
CITY_21MC100_002458862