NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling locations, asbestos, Jan 17, 2002

Machine-extracted title · confidence 39%

EPA air sampling results for NYC/ER show multiple locations with below TEM AHERA standards; some samples not collected due to malfunctions or access.

NYC-WTC_000321269–000321270
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

] Jessica ‘-eighton - RA_sitrep01-17.wpd Pagel]

'1

ParkRow (Site 1) Chambers St./West St. (Site 2) Public School 154: 333 East 135^^ St, Bronx (Site 5) Intermediate School 143: 511 West 182— St., Manhattan (Site 6) Public School 274: 800 Bushwick Ave.. Brooklyn (Site 7) Public School 44: 80 Maple Parkway. Staten Island (Site 8) Public School 199: 3290 - 48"' Ave., Queens (Site 9) o During this period a total of 12 samples were collected from these monitoring sites. o All of the samples were below the TEM AHERA standard. o Samples were not collected from Sites 7 and 8 on January 12 due to equipment malfunctions.

NYC / ER (Jan 16) - Particulate Monitoring (Dataram)

o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 6 to 6/2 hours. o Station L values ranged from 0.0 to 96.6 ug/m’ with an average of 8.9 ug/m^ o Station N values ranged from 0.0 to 117.3 ug/m’ with an average of 6.9 ug/m\ o Station R values ranged from 0.0 to 121.5 ug/m’with an average of 10.1 ug/m\

NYC / ER (Jan 16) - Volatile Organics (Mobile Laboratory)

o Volatile organic compounds were not detected above the detection limit (20 ppbv) in any of the four samples collected (Washing Tent, Austin Tobin Plaza, North Tower, and South Tower), including in the debris area at ground level.

Direct Reading Instruments

NYC / ER (Jan 16)

o Low levels of carbon monoxide noted at all stations during the morning monitoring period. o Otherwise, nothing of significance reported.

i I i

CITY_21MC100_002458860

NYC-WTC_000321270

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321270Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321349

Feb 13–14 asbestos samples below TEM AHERA; equipment malfunctions noted for several locations.

Similar indexed content

NYC-WTC_000199709

Situation report on asbestos air sampling results and equipment status for New York City Emergency Response sites in early April 2002.

Similar indexed content

Compare copies and versions →