o 1 ambient location at Location R.
o All samples collected in the breathing zone.
o VOCs in all 4 work-zone samples were either not detected or were below applicable
OSHA PELs. As a further point of comparison, since several locations are at or near
the perimeter, the results were all below EPA Removal Action level guidelines.
o 1,1,2,2-Tetrachloroethane exceeded the EPA Removal Action level guidelines (based
on a 30-year exposure) at Location R. Note: RAL is 0.45 ppbv.
o 1,1,2,2-Tetrachloroethane did not exceed the EPA Removal Action level guidelines
adjusted to a 1-year exposure duration.
o All other VOCs at Location R were either not detected or below the EPA Removal
Action level guidelines (based on a 30-year exposure).
o Wind conditions at the time of this sampling event place Location R upwind of the
WTC work zone.
o VOC concentrations in the work zone, including those at or near the perimeter, are
significantly reduced as compared to results from daily grab samples collected on the
debris pile in the plume at ground level.
o Note: These breathing zone samples are influenced by ambient conditions and
vehicular emissions over a period of 8 hours as compared to the TAGA/mobile
laboratory samples which are ground level plume samples in the debris collected over
a period of one minute.
NYC / ER (Dec 17) - Volatile Organic Compounds
o 5 (Summa) samples collected over a period of approximately 8 hours.
0 4 work-zone locations, several at or near the perimeter (South Tower - South Side
(aka: South), South Tower - Southwest Side (aka: SW Comer), North Tower -
Northwest Side (aka: NW Comer)), and one at Austin Tobin Plaza (aka: East).
o 1 ambient location at Location R.
o All samples collected in the breathing zone.
o VOCs in all 4 work-zone samples were either not detected or were below applicable
OSHA PELS. As a further point of comparison, since several locations are at or near
the perimeter, the results were all below EPA Removal Action level guidelines.
o VOCs at Location R were either not detected or below the EPA Removal Action level
guidelines (based on a 30-year exposure).
o VOC concentrations in the work zone, including those at or near the perimeter, are
significantly reduced as compared to results from daily grab samples collected on the
debris pile in the plume at ground level.
o Note: These breathing zone samples are influenced by ambient conditions and
vehicular emissions over a period of approximately 8 hours as compared to the
TAGA/mobile laboratory samples which are ground level plume samples in the debris
collected over a period of one minute.
NYC / ER (Dec 4) - Dioxin
CITY_21MC100_002458842
NYC-WTC_000321258