NYC 9/11 Public Portal Document
Dioxin Air Monitoring Data Summary for Lower Manhattan WTC Sampling
Totals (for sampling through 01/08/02, in ng/m3)
Total Samples - All Sites 260
Samples Above Screening 2 I
Level - All Lower Manhattan
Sites:
% Above Screening Level 0.77%
Samples Below 258
Maximum Value: (10/4/02) 0.18
Minumum Value: 0.00002
Screening Level*: 0.16
Average All Samples 0.00782
1%
■ Samples Above Dioxin refers to a group of chemicals created
Screening Level - when many types of materials burn; it is also
All Lower created during some types of manufacturing
Manhattan Sites; and incineration. Dioxin does not break down
■ Samples Below
easily, remains in the environment and can be
distributed by wind and water. It is found in a
wide variety of places. People are exposed to
dioxin primarily by eating meat, dairy and fish.
99%
The burning of building and office debris at the World Trade Center is causing some emissions
of dioxin. Most of the air samples taken in areas surrounding the work zone and analyzed for
dioxin have been below EPA's screening level, which is set to protect against significantly
increased risks of cancer and other adverse health effects. The screening level is based on an
assumption of continuous exposure for a year to an average concentration of 0.16 nanograms
per cubic meter (ng/m3).** Because the vast majority of individual as well as the average***
measured dioxin levels have been lower than the screening level, EPA does not expect an
increased risk of health problems as a result of dioxin being emitted from the World Trade
Center site.
*The information contained in this database should be considered provisional and may be
subject to adjustment upon final analysis.
** The unit ng/m3 is the mass of dioxin/furan compounds in nanograms (a billionth of a gram)
per cubic meter of air. Measurements of the dioxin/furan compounds are grouped together into
a single value termed "dioxin toxic equivalents" or dioxin TEQs.
*** For the purposes of evaluating exposure an average concentration of many samples more
closely represents exposure over a longer period. This longer term average is less than the
maximum concentration that could be contacted at any one time, but because the screening
level assumes continuous exposure for a year, the average of the measured concentrations is
more appropriate for evaluating risk than an individual measurement.
CITY_21MC100_002458620
NYC-WTC_000320932
OCR can misread numbers and units. Confirm readings against the page image before using them.