Lead air monitoring data, Lower NYC WTC

Machine-extracted title · confidence 34%

Lead in air monitoring data summary for Lower Manhattan WTC with averages and % above.

NYC-WTC_000320908
Page image
Scanned page image, NYC-WTC_000320908
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Lead Air Monitoring Data Summary for Lower Manhattan WTC Sampiing

Totals (for sampling through 01/15/02, in ug/m3) Total Samples 261 Samples Above Screening Level 5 % Above 1.92% Samples Below 256 Maximum Value (09/23/01): 5.4 Minumum Value: 0.006 Screening Level*: 1.5 Average AHI 0.18

2%

\ ''9 ■Samples Above Most of the lead in our air used to Screening Lewi come from vehicles using leaded gasoline. However, EPA ■Samples Below eliminated the use of leaded gasoline and lead levels in outdoor air and in much of the population have declined dramatically. Today, metal processing, refining and recycling facilities are the major source of 96% lead in the air. Children under the age of seven are at the greatest risk from lead poisoning and their primary exposure is from leaded-paint dust and chips in older housing.

EPA has established an air quality standard for lead of 1.5 ug/m3, averaged over a three month period. This is based primarily on how long-term exposure to lead affects the most sensitive population (including children). The values given below are for short-term (e.g., 12-hour) measurements. In the first weeks of the cleanup effort, some short-term lead measurements were higher than this standard; however, the standard is based on a three month average and we expect that the concentrations will continue to drop as the cleanup continues. EPA does not expect people to have increased risks of health problems due to lead exposure from the World Trade Center cleanup effort.

CITY_21MC100_002458599

NYC-WTC_000320908

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320908Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320955

Lead air monitoring data summary for Lower Manhattan WTC through 01/15/02, with lead concentration and percent above.

Similar indexed content

NYC-WTC_000320930

Lead air monitoring data summary for Lower Manhattan WTC through 01/15/02.

Similar indexed content

NYC-WTC_000320981

Lead air monitoring data summary for Lower Manhattan WTC through 01/15/02.

Similar indexed content

NYC-WTC_000320916

Lead air monitoring includes totals, site values, and EPA-related notes on gasoline sources.

Similar indexed content

NYC-WTC_000320939

Lead air monitoring data summary for Lower Manhattan WTC through 01/15/02.

Similar indexed content

Compare copies and versions →