Ambient air testing, high school lead and dust

Machine-extracted title · confidence 37%

Ambient air testing and settled dust/bulk sampling for asbestos at a high school facility.

NYC-WTC_000320841–000320847
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z o o g o I "0 o c o CT o Ca3 ro o' o "0 oo o HIGH SCHOOL FOR LEADERSHIP & PUBLIC SERVICE 9L D MERCURY PCB’s AND SILICA FIBER TOXIC ORGANIC DIOXINS SAMPLES HYDROCARBONS (HC) AND o o CYANIDE (RESPIRABLE GLASS COMPOUND (TVOC) AND METALS c DUST) POLYNUCLEAR 3 o 3 AROMATIC HYDROCARBONS (PAHs) Mercury Concentration Range of Range of Results Indoor Outdoor Indoor Air Plenum Indoor Readings Outdoor Cone Indoor Outdoor Readings Reading Surfaces Cone. Reading (mg/m’) Cone. Cone. Range of Cone.

7 indoor air samples 2 outdoor air 9 air samples for dioxin were of PAHs were samples of collected. All indoor and outdoor collected. Napthalene PAHs were concentrations were below the EPA and 2- collected. 2- screening level of 0.16 ng/m3. methylnapthalene methylnapthale were detected in all of ne was detected the indoor samples. outdoor by the Main Entrance. 9 air samples 9 air samples (7 indoors and 2 outdoors) W’ere for mercury collected for metals. The metals that were were collected. found above the limits of detection were No sample chromium, copper, iron, and zinc. contained mercury at a 9 air samples for hydrocartxrn analysis were concentration collected. The HCs detected were acetone greater than that (0.140 ppm), hexane (0.078 ppm), and total detected in the other A hydrocarbons (0.080 ppm). They blank. were found in the hallway by stair B on the 3"* floor. No HCs were detected in any of the other six indoor samples or in the two outdoor samples.

o

S o o o I o o o on

o cn

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320844Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320880

Ambient TEM and bulk asbestos results, with settled dust findings at PS150M.

Similar indexed content

NYC-WTC_000320873

Ambient TEM results and bulk sampling for asbestos across multiple dates at PS150M.

Similar indexed content

NYC-WTC_000320852

Asbestos TEM and bulk sampling results for a NYC public school, with debris and roof sampling.

Similar indexed content

Compare copies and versions →