NYC 9/11 Public Portal Document
debris. See information below for polynuclear aromatics, Freon R-22, phosgene and
dioxin.
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning truck
wash stations revealed trace levels of nitric oxide and nitrogen dioxide. SO, personal
and area results were found to be below OSHA limits.
Metals: As of 12/9/01 OSHA has taken 565 air samples to monitor worker exposures to dusts,
fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium,
cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium,
magnesium, arsenic, and mercury. Results from these samples are generally well below
the applicable OSHA limits. However, torch cutting and burning structural steel at the
rubble pile have resulted in instances ofoverexposures as follows: copper (7); iron oxide
(10); lead (11); and cadmium (2). Accordingly, OSHA is recommending that workers
engaged in these operations wear appropriate respiratory protection.
Ionizing Radiation; A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation
with particular attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken samples for dioxin and these samples were analyzed by EPA. One
initial sample, representing exposure directly on the pile, showed elevated levels of
dioxins when compared to ambient background levels. This value was comparable to
the levels found by EPA sampling. The dioxins at this location are being emitted from
the on-going rubble fire. Additional sampling was conducted around the perimeter of
the pile and revealed levels that were considerably lower than those on the rubble pile.
Dioxins are considered collectively as suspect human carcinogens. OSHA does not
have a worker standard for dioxins. OSHA is coordinating with EPA, and the Salt Lake
City Analytical Laboratory to fully assess the risk posed by the elevated levels of
dioxins.
Polynuclear
Aromatic
Hydrocarbons: OSHA has taken 96 samples. Sample results to date have identified several elevated
samples, four of which reached or exceeded OSHA’s coal tar pitch volatile PEL of
0.2mg/m’ These personal samples were taken on the pile on iron workers and grappler
operators. OSHA continues to strongly recommend the use of respiratory protection
when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
<& Phosgene: OSHA has taken 79 samples for Freon R-22 (chlorodiflouromethane). Sample results
received to December 5* reveal non-detectable airborne levels. During operations
involving Freon removal from the auxiliary chiller that started on 12/5/01, direct reading
instrument revealed readings ranging from 100 ppm to one peak near a leaky valve of500 ppm.
SCBA tanks were and are being worn by workers, and masks are to be worn only when direct
reading instruments reveal 850 ppm Freon and/or less than 20.4% Oxygen. OSHA does not
have an exposure limit for Freon R-22. (The NIOSH REL for Freon is 1 OOOppm..) In response
to information about exposure to the decomposition by-products of Freon R-22 used in
the air conditioning systems of WTC towers, sampling for hydrofluoric acid (HF) had
been conducted. Results for HF revealed non-detectable levels. Sample results for
phosgene to date show non-detectable levels.
Page 2 of 2
CITY_21MC100_003050971
NYC-WTC_000320739
OCR can misread numbers and units. Confirm readings against the page image before using them.