NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

VOC Monitoring near WTC, Sept 28 2001

Machine-extracted title · confidence 28%

Summary of VOC air samples taken around WTC site to assess exposure of nearby communities.

NYC-WTC_000320530–000320537
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Conclusion

The results of the monitoring suggest that the levels of some VOCs in the plume at the debris pile are significantly elevated above typical background levels, and workers at the site should take precautions to limit their exposure. For the VOCs that were measured, the air concentrations outside the work area are not a significant health concern. However, the elevation above background levels of some VOCs suggests that combustion products may be contributing to symptoms of eye, nose and throat irritation that have been reported in workers and residents in the WTC neighborhood. Based on the cuiTent results and the expected mitigation of VOC emissions from the site in the future by controlling the fires, continued monitoring for the VOCs sampled is not necessary at this time. However, it may be useful to confirm these findings, to assess levels of other volatile compounds such as known respiratory irritants and to assess VOC concentrations once the fires are controlled to ensure that other recovery activities are not a continuing source of VOCs in the community.

References

Peter S.J. Lees. 1995. Combustion products and other firefighter exposures: A state of the art review. Occup. Med. 10:691-706.

November 20, 2001

5

CITY_21MC100'2004053559

NYC-WTC_000320535

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320535Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

VOC monitoring summary near WTC, Sep 28, 2001

NYC-WTC_000204863

Summary report of volatile organic compound monitoring conducted by State and City Health Departments around the World Trade Center site on September 28, 2001.