tridymite on hard surfaces.

6.3.7 Total Dust Wipe - There were nine wipe samples collected from residential areas and analyzed for total dust. Dust was detected in all nine samples with a mean concentration of 10.9 mg/ft\ The 95% UCL for this data set was 14.4 mg/ft\ which can be used as an estimate of the background concentration of total dust.

7.0 HISTORICAL STUDIES ON BACKGROUND CHARACTERIZATION 7.1 Background Literature Search Results The WTC Background Study was conducted to address the following question: What were the baseline levels for a select group of contaminants in residential dwellings in lower Manhattan had the Trade Center never collapsed? If data were available that captured the baseline levels of WTC Contaminants of Potential Coneem (COPCs) in the settled dust and indoor air of residential dwellings in lower Manhattan prior4o,9/l 1/01, the WTC Background Study would not have been necessary. No 'sucfr study exists, thus warranting the WTC Background. However, there are yafiqus sources of data that partially address the specific aim of , the WTC Background.Stiidy., This section evaluates the findings of historical studies on background by way of a comparison to the methods and results of the WTC Background Study.

A search of the literature was conducted for published data on residential indoor measurements of WTC COPCs. TheTocus was for relevant data that may be used for comparison with the measurernents from the WTC Background Study. Worth noting are the multiple factors that limit the representativeness of historical studies to the WTC Background Study. They include: variations in sampling and analytical methods; characteristics of the housing stoek7(e.'g!, age, type and upkeep) and seasonal variability. '

7.1.1 Residential Indoor Airborne Asbestos Measurements The literature citations on airborne asbestos measurements focused mainly on occupational environments. Some information is available for schools and other public buildings. Very few studies described measurements made in residential settings. . / B .

There are a number of analytical techniques (PCM, TEM, direct preparation, and indirect preparation), as well as different units of measurements reported in the literature for airborne asbestos concentration. HEI (1991) listed eleven different measurement units that could be encountered in the literature for asbestos fibers analyzed by TEM. Another factor to note is how the average or mean value is determined from a set of measurements. Some studies treat all samples with no asbestos structures/fibers counted as 0 s/cc or 0 free and not as a “less than” detection limit (Van Orden et al. 1995).

WORLD TRADE CENTER BACKGROUND STUDY 28

CITY_21MC100_004053184

NYC-WTC_000320418

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320418Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →