Draft: Do not Cite, Quote, or Release June 12, 2002 Last saved by SERodenbeck at 11:15 am

45 along with the analytical results to put the sampling results into the context of where and 46 how the samples were obtained, and general condition of the sampling locations. 47 48 Air and settled dust samples were collected and analyzed for the following materials used 49 in the WTC construction; asbestos, MMVF, crystalline quartz (a type of silica), calcite, 50 portlandite, gypsum, mica, and halite. MMVF fe.g., fiberglass) is used in thousands of 51 products because of its chemical resistance, strength, and ability to insulate against heat 52 and sound. All of the crystalline minerals analyzed in this project are common materials 53 used in building construction. Quartz, or silica, is a naturally occurring mineral used in 54 glass manufacturing and is also a component of cement. Cristobalite and tridymite are 55 different crystalline forms of quartz. Calcite, Portlandite and lime are naturally 56 occurring, high pH minerals used in cements and mortars. Gypsum is a naturally 57 occurring mineral used in plaster, wallboard, and in some cements. Mica is a group of 58 naturally occurring minerals that are used in paint. Joint cements, plastics, roofing, and 59 rubber. Halite (also known as rock salt or sodium chloride) is used in ceramic glazes, fire 60 extinguishing, metallurgy, and highway de-icing and table salt. 61 62 In addition to analyzing the samples for the fibers and minerals found in common 63 building materials, when a sufficient quantity of dust was present, it was mixed with 64 water and the pH of the resulting mixture was measured. 65 66 Air samples 67 68 Air samples were collected using vacuum pumps to draw air past a filter positioned at an 69 adult’s breathing level. In addition to a filter for fiber analysis, multiple particulate 70 samplers were placed at each sampling location to collect different particle sizes 71 including respirable (PM4 and PM2.5), thoracic (PMIO), and total inhalable (PMIOO). 72 This resulted in the collection of overlapping, or nested, particulate size fractions. 73 74 The particle size determines how deeply a particle can travel into the respiratory tract. 75 Respirable particles with diameters of four microns or less (PM 4) are very small particles 76 that can be breathed in and can travel deeply into the air sacs of the lung. In a very few 77 instances another sampler was used that collected a smaller set of respirable particles, 78 those with diameters of two and one half microns or less (PM2.5). Another sampler 79 collected particles with diameters of ten microns or less (PMIO). This sampler would 80 collect not only respirable particles, but also those slightly larger particles that tend to 81 land in the upper regions of the respiratory tract, including the throat. A third sampler 82 collected a larger set of particles, those 100 microns or less in diameter (PMIOO). The 83 larger particles in this fraction can land in the nose and throat. Where a particle lands 84 determines what types of health effects might be experienced. Particles too large to travel 85 into the narrower passages of the lower respiratory tract might deposit in the upper 86 airways, (e.g. the nose and throat) and cause irritation. Similarly, larger particles might 87 cause eye irritation. If the dust contains sufficient amounts of particles of a very small 88 size, then effects consistent with particles reaching the lower respiratory tract might occur 89 (coughing, shortness of breath). 90

CITY_21MC100_012170987

NYC-WTC_000320163

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320163Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →