Draft: Do not Cite, Quote, or Release June 12, 2002 Last saved by SERodenbeck at 11:15 am

results of the nuisance dust sampling can not be used to reliably estimate the actual concentration of any of the particulate matter size fractions; so that entire data set was rejected from further consideration.

After the filters were weighed to record their final weight, they were analyzed by XRD to identify the mass of the various mineral components captured by the filter. Both the blanks and sample filters were analyzed further to identify if, and how, the XRD results could be used to describe the type, and concentration, of materials in the sampled spaces. The XRD process does not depend on the weight gain of the filter, and is a separate analytical procedure that is used to identify and quantify the relative percentage of various minerals on a filter.

The inconsistencies of the data cause us to question if the correct filter was used with the correct pump, and if the sample was really taken from the labeled location. It is important that the correct filter be used with a pump to ensure that the air volume the pump is calibrated to draw through the filter, is actually drawn through the filter. If more air is drawn through the filter than expected, more mass will be deposited on the filter and the calculated concentration will be higher than the actual concentration of the sampling location. If too little air is drawn through the filter, less mass than expected will be deposited on the filter and the calculated concentration will be less than the actual concentration of the sampling location. In addition, if the errors are the result of filters being mixed-up during the sampling or analytical process, the (incorrectly) calculated concentration will represent the wrong location.

There is no real test that we can perform with the data to verify that the XRD results accurately reflect the mineral concentration of a particular sampling location. However, the ability of the XRD methodology to identify mineral components and their relative mass, on a particular filter is not lost. All that is lost is our ability to calculate the mineral concentration and the exact location of that sample. For these reasons the XRD analysis was used solely to identify what mineral components were commonly detected in the sampled buildings of Lower Manhattan compared to the background buildings. The results of the XRD analysis of airborne dust will be presented in the next section with the results of the XRD analysis of the settled dust.

A variety of individuals and organizations invested great deal of time and energy to develop the nuisance dust portion of the sampling plan, conduct the sampling, and analyze the results. After all of that work, it is very disappointing to find that the results are not use-able. Naturally, a great deal of effort has also been expended to identify ‘what went wrong’. Unfortunately, QA/QC procedures can typically only identify results that have been affected by some type of inconsistency; they cannot describe much about the error source. As described earlier in this section, blanks are used to: 1) assess the ability of the sampling and laboratory analysis

CITY_21MC100_012171056

NYC-WTC_000320232

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320232Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →