Draft: Do not Cite, Quote, or Release June 12, 2002 Last saved by SERodenbeck at 11:15 am

cause and extent of inconsistencies of the measured results. We were not able to identify a sub-set of the measured results that we believe are not potentially affected by these inconsistencies - so we had to reject the entire data set describing nuisance dust concentrations and limit our use of the mineral component analysis. In addition we were not able to completely identify the specific cause of the inconsistencies; it may be due to a combination of factors.

The following information is provided to illustrate why the airborne nuisance dust results were rejected, why the mineral component analysis was used in a limited way, and some of the potential sources of error that could have contributed to the data inconsistencies.

Ideally the nuisance dust data would have provided information about the airborne concentration of particulate matter (PM) with an aerodynamic diameter of 100 urn and less (PMIOO), of 10 um and less (PMIO), of 4 um and less (PM4), and of 2.5 um and less (PM2.5). Each of these size fractions (PMIOO, PMIO, PM4 and PM2.5) are collected using slightly different equipment, but they all follow the same basic procedure of using a pump to draw air into a sampling head and deposit particulate matter of the appropriate size fraction onto a filter. The difference in filter weight, before and after the sampling weight, represents the mass of the particulate matter that was captured by the filter. Knowing the pre- and post-sampling calibration of the pump and the sample collection time allows us to calculate the volume of air that was drawn through the filter. The concentration of that size fraction in the sampled air is then calculated by dividing the mass by the volume. It is important to understand the concept of this sample collection and analysis procedure to understand why the data was rejected.

In addition to the filters that were used to measure the airborne concentration of nuisance dust, two filters were also sent by the lab to the sampling team to be used as blanks. The blanks traveled with the sample filters, went to the sampled building and were treated just like a sample filter - except that they were not used. Ideally the difference between the pre- and post-weight of the blanks filters should be zero because they were not used.

Figure 1 (below) is a frequency distribution of the weight gain (final weight - initial weight; this could actually result in a ‘loss of weight’, but we’ll refer to the measurement as ‘weight gain’) of all but 7 of the blanks. Those 7 blanks were not included because their weight gain (-90 mg to 5.99 mg) was greater than the limits shown in this figure (-.2 mg to .4 mg). The vertical axis represents the number of blanks that had a weight gain within .01 mg of the weight gain shown on the horizontal axis.

CITY_21MC100_012171054

NYC-WTC_000320230

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320230Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →