Draft: Do not Cite, Quote, or Release June 12, 2002 Last saved by SERodenbeck at 11:15 am

504 A series of three concentric circles was drawn around the WTC location. The 505 circles were then divided by direction or zone from the WTC (north, south, and 506 west). Attempts were made to select the same number of residential buildings per 507 zone for sampling. Four “comparison area” residential buildings were selected for 508 testing to begin to determine what levels of fibers and minerals might be routinely 509 found in a large city. 510 511 Once a building was selected, air and settled surface dust sampling occurred in up 512 to 4 different locations: an area outdoors near a/the main entryway to the building; 513 an area inside of the main entry (or other common area); and 2 residential units. 514 Informed consent for sampling was obtained and questions were administered 515 (e.g., were windows open on the morning of September 11, 2001) that were to 516 assist in interpreting the results. 517 518 Both air and settled surface dust samples were collected in high traffic or routinely 519 used areas of the space. For example, settled surface dust v/as collected from 520 areas where individuals frequently walked, not from behind furniture or 521 underneath kitchen appliances. Air sample inlets were at approximately 4 feet in 522 height above the ground/floor surface to provide results more reflective of what 523 might be inhaled. 524 525 Attempts were made during air sampling to obtain data that would reflect what 526 might be in the air during periods of high activity. If the selected area was not 527 occupied at the time of sampling, and if there was no central heating or air 528 conditioning system that could result in contaminant migration into another 529 occupied area, aggressive air sampling was conducted. If the area was occupied, 530 the heating or air conditioning system fan was turned on during the period of 531 sampling. This would not represent a period of high activity, but would present 532 data that might be found during typical or normal activity. 533 534 Samples Taken 535 536 Sample collection was conducted from November 4, 2001 to December 11, 2001 537 for the lower Manhattan area and from December 6-10, 2001 for the comparison 538 buildings. Thirty buildings in Lower Manhattan were sampled and 4 comparison 539 buildings were sampled from the area north of 59th Street. In the 30 Lower 540 Manhattan buildings, the following locations wS'e sampled: 59 Residential units, 541 29 Common areas, and 29 Outdoor areas. 542 543 There were 127 air samples taken from 117 different areas of the lower Manhattan 544 buildings. Ten of the areas had co-located sampling equipment. In the 59 545 different residential units, there were 64 air samples taken. Thirty air samples 546 were taken from 29 different common areas. 547

CITY_21MC100_012170998

NYC-WTC_000320174

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320174Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →