EPA dioxin cleanup criteria memo, 2002

Machine-extracted title · confidence 28%

Memo outlining suggested very low cleanup levels for dioxins on interior surfaces after WTC events.

NYC-WTC_000320135–000320137
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Use of 1988 Notional Research Council cleanup levels

In your communications, you suggested the use of 25 ng/m^ as a safe level for dioxins on surfaces for the 100 Church Street address. You quoted the recommendations made in 1988 by the National Research Council (NRC) of the National Academy of Sciences (NAS) for the cleanup of the Binghamton, New York office building which was contaminated after a transformer fire in 1981.'’ This would be inappropriate for several reasons.

First, and most importantly, this 25 ng/m^ would be much higher than normal background levels for dioxins on smooth interior surfaces. The study of the two apartments after the WTC collapse, discussed above, had much, much lower levels of dioxin than 25 ng/m^, which were probably higher than typical background levels in Manhattan. The proposed EPA risk reassessment for dioxins determined that humans are already at risk for adverse health effects from dioxins at typical background levels,^ so it would be inappropriate to use any cleanup levels higher than background.

Second, the NRC has apparently withdrawn their 1988 recommendations. The NAS Press no longer offers the publication which made these recommendations, although earlier titles by the NRC are still offered. As I recollect personally, there was much controversy over the cleanup of the Binghamton office building, and the NRC recommendations did not necessarily hold sway. Further, the recommendations were based on outdated science.

Third, without being able to examine the NRC recommendations themselves, it is very difficult to determine their exact nature, or whether they would be applicable to the building at 100 Church St. The NRC most likely recommended that all porous materials be disposed of, and that non-porous surfaces with the 25 ng/m^ level be re-painted in high occupancy areas.

Cleanup methods

The EPA has rigorous guidance on cleanup methods and disposal of PCB-contaminated surfaces, materials, etc. in the interior of buildings in both the Code of Federal Regulations as well as guidance documents. These are listed in the references.^ These could be helpful in the cleanup up of 100 Church Street. I am not aware of any similar set of procedures developed by EPA to address the cleanup of dioxins.

-3 -

CITY_21MC100_003050640

NYC-WTC_000320137

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320137Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →