NYC-WTC_000337617
Sampling plan table for 14 buildings and 42 units total.
20 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Draft assessment describing monitoring of air, dust, water around the WTC site and minimal long-term risk.
NYC-WTC_000320123–000320134OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
[[Nancy Jeffery - PIC-rptO513O2dft.wpd Pc3ge9
Asbestos
Tier Action Asbestos (settled dust) Asbestos (indoor air) Screening Basis Screening Basis Value Value I Aggressive > 100,000 Risk-based > 0.0004 f/cc * Risk-based cleaning. If levels f/cm2 screening level screening level persist, take for residential for short term additional action to setting (E-04 x 1 exposures (< = reduce exposure. yr) 1 yr) may result in exposures which contribute to long-term risk. n Maintain 10,000 to Risk- based NYC *Risk- based recommended 100,000 f/cm2 screening level background to screening level cleaning methods. for residential 0.0004 f/cc * for residential Consider setting (E-04 x setting (E-04 x additional 30 yr) 30 yr). monitoring m No further action < or = < or = NYC required. background or background 1000 f/cm2 * f/cc = fibers (greater than 5 micrometers long) per cubic centimeter of air. Note that fibers and structures are used interchangeably in this report.
For asbestos in indoor air, the Asbestos Hazard Emergency Response Act (AHERA) standard of 70 structures per square millimeters (S/mm2), as measured by Transmission Electron Microscopy (TEM) analysis, has been used since the 1980s to confirm effective abatement of asbestos-containing material in schools. The standard represented the highest detectable level of background contamination on blank filters at the time (in the 1980s), not a risk-based analysis.
In order to develop risk-based benchmarks for this report, the AHERA standard was compared to a risk-based approach called Phase Contrast Microscopy (PCM). PCM was used for airborne asbestos analysis in most of the occupational epidemiology studies that provide robust dose-response data on asbestos-related carcinogenesis. AHERA’s TEM fiber counts were converted to structures that would be visualized had the analysis been done by PCM. It should be noted that the correlation between total PCM fiber and TEM fiber counts is very uncertain and is likely to vary from one venue to another; therefore, no standard conversion factor exists for these two measurements.
The process for estimating cancer risk based on the AHERA standard includes 1) harmonizing the standard (TEM counts) with the dose-response metric (PCM counts); 2) converting units of measurement from fibers per unit area of filter paper to fibers per unit volume of air; and 3) calculating an airborne asbestos concentration that relates to an upper-bound estimate of exposure duration and acceptable risk level.
CITY_21MC100_003050602
NYC-WTC_000320131
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000337617
Sampling plan table for 14 buildings and 42 units total.
20 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176160
Draft assessment summarizing eight months of monitoring data regarding air, dust, and water contaminants at the WTC site and surrounding areas.
25 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242900
Draft section describing selection of contaminants of potential concern.
25 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
25 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
25 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317656
Draft COPCs selection and discussion of indoor environmental risks post-9/11.
25 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242774
Laboratory assessment of contaminants related to World Trade Center dust, prepared by COPC committee participants.
25 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199582
Report prepared by a committee detailing contaminants of concern associated with the World Trade Center site.
25 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164840
Laboratory report and communications overview for environmental testing related to NYC DEP.
25 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
25 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
25 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
25 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000164840
Laboratory report and communications overview for environmental testing related to NYC DEP.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337617
Sampling plan table for 14 buildings and 42 units total.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000332097
Risk-based screening levels for aggressive cleaning and ongoing exposure mitigation.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152855
NY DOH/NY EPA doc on asbestos clearance criteria for indoor clean-up.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000164840
Laboratory report and communications overview for environmental testing related to NYC DEP.
Similar indexed content
NYC-WTC_000337617
Sampling plan table for 14 buildings and 42 units total.
Similar indexed content
NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
Similar indexed content
NYC-WTC_000176160
Draft assessment summarizing eight months of monitoring data regarding air, dust, and water contaminants at the WTC site and surrounding areas.
Similar indexed content
NYC-WTC_000242900
Draft section describing selection of contaminants of potential concern.
Similar indexed content