NYC-WTC_000319401
DOHMH/ATSDR air and settled dust sampling results near 88 Greenwich.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Results report for air and settled dust samples around 30 WTC-impacted buildings.
NYC-WTC_000319521–000319525OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Overall, when elevated air levels of fibers were found in lower Manhattan (in six areas) the additional analysis showed that the elevations were more likely due to cellulose, textiles, and other fibers rather than asbestos or fibrous glass. Upper respiratory tract irritation due to inhaled fibers has been reported in instances when fiber concentrations were far greater than any of the Eimounts found in the results of this investigation.
Table 2a Fibers in Air for 66 Frankfort and 90 Gold Streets and the upper Manhattan Comparison Area (fibers per cubic centimeter of air)
66 Frankfort and 90 Gold Streets* Comnarison Area* Fibers in Air Common Outdoor Residence Residence Common Outdoor Residences Area #1 #2 Area Total Fibers <0.001 <0.001 <0.001 <0.001 0.002 0.001 0.003 (PCM) Asbestos NA NA NA NA NA NA NA (TEM) SVF (SEM) NA NA NA NA 0.00004 0.00004 0.00009 ♦Results are maximum values found in location PCM = phase contrast microscopy TEM = transmission electron microscopy SEM = scanning electron microscopy NA = not analyzed SVF = synthetic vitreous fibers
Fibers in Settled Dust
Table 2b describes the sampling results for fibers in settled dust at your buildings. Low levels of asbestos were found in some settled dust samples in Lower Manhattan, primarily below Chambers Street. Polarized light microscopy (PLM), a method that can distinguish between fiber types, was used to determine the presence of synthetic vitreous fibers (SVF) and asbestos. If the presence of asbestos was found at levels of less than 1%, a more sensitive method (TEM methodology) was used to determine the presence of asbestos. Occasionally it was not possible to .analyze the material by TEM methodology (e.g. not enough material present). The presence of SVF (primarily fiberglass) was identified in many of the samples collected in lower Manhattan. No SVF or asbestos was detected in the settled dust in comparison areas.
Although the airborne levels of asbestos and SVF did not present a health concern (see Conclusions/Recommendations), the presence of these materials in the settled dust in some locations indicates the need for continued frequent cleaning with HEPA vacuums and damp cloths/mops to reduce the potential for exposure.
CITY_21MC100_002452762
NYC-WTC_000319524
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000319401
DOHMH/ATSDR air and settled dust sampling results near 88 Greenwich.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319390
DOHMH/ATSDR report on air and settled dust sampling around World Trade Center buildings.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208359
Report on air and dust sampling results from residential buildings in lower Manhattan conducted by the Department of Health.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353759
DOHMH/ATSDR collaboration results of air and settled dust sampling near World Trade Center sites.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242212
DOHMH/ATSDR report on residential dust sampling after WTC collapse.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353828
DOHMH and ATSDR air and settled dust testing around WTC site; results for your building reported.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353850
WTC-related air and settled dust testing; results for building reported.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353833
DOHMH and ATSDR air and settled dust testing around WTC site; results for your building reported.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319156
DOHMH and ATSDR air and dust testing near WTC; results reported for 258 [name] building.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338367
DOHMH/ATSDR report on air and settled dust sampling around WTC residential buildings.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353838
DOHMH and ATSDR air and settled dust testing around WTC site; results for your building reported.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319142
Results report for air and settled dust sampling at 80 Warren Street, late 2001.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000208359
Report on air and dust sampling results from residential buildings in lower Manhattan conducted by the Department of Health.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353764
Continuation of WTC-related air and settled-dust sampling results for 31 N. [name].
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319142
Results report for air and settled dust sampling at 80 Warren Street, late 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353759
DOHMH/ATSDR collaboration results of air and settled dust sampling near World Trade Center sites.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319137
Preliminary results report for air and settled dust sampling at 80 Warren Street, Nov–Dec 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353850
WTC-related air and settled dust testing; results for building reported.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000319401
DOHMH/ATSDR air and settled dust sampling results near 88 Greenwich.
Similar indexed content
DOHMH/ATSDR report on air and settled dust sampling around World Trade Center buildings.
Similar indexed content
NYC-WTC_000208359
Report on air and dust sampling results from residential buildings in lower Manhattan conducted by the Department of Health.
Similar indexed content
NYC-WTC_000353759
DOHMH/ATSDR collaboration results of air and settled dust sampling near World Trade Center sites.
Similar indexed content
NYC-WTC_000242212
DOHMH/ATSDR report on residential dust sampling after WTC collapse.
Similar indexed content