Summary ofAsbestos Sampling Results Page 2 of 3
Address: 258 Broadway Date sampled: November J5, 2001
fZcc using the PCM methodology, additional analysis was performed to determine whether any of
the fibers were asbestos. In this building, additional analysis was not warranted since the air
sampling results in your building were not greater than 0.003 fi^cc.
R£SultsofPhase^ontrast Microsco£y^CM)testingofairat258BroadwaYj^oy^5^001
Area Sampled Outside Common Residence 1 Residence 2
Sample Numbers A-0-4 A-C-4 A-Rl-4 A-R2-4
A-O-X-4* A-C-X-4*
Concentration of Fibers 0.001 0.001 <0.001 0.001
(fZcc)** in air at this <0.001* 0.001*
location
Concentration of Fibers <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003
(fZcc) in air at comparison
locations
NYC Re-occupancy 0.01 0.01 0.01 0.01
Standard (f/cc) ***
* Denotes a second air sample taken in the same location for quality control purposes.
** Fee is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air
filter and the volume of air pulled through the filter measured in cubic centimeters of air.
*** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work
(Rules of the City of New York, Title 15, Chapter 1)
ASBESTOS DUST TEST RESULTS
In general, the dust and debris samples were examined by two different laboratory methods for
asbestos fibers. Polarized Light Microscopy (PLM) and Transmission Electron Microscopy
(TEM). PLM is used to define asbestos containing material in dust and debris. A material is
considered to be asbestos containing material if it contains more than 1% asbestos using the PLM
method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM
were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does
count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust
samples.
No asbestos fibers were found in the dust samples from the hallway or in the two residences by
the PLM laboratory method. Not enough dust was found outdoors, so a sample was not
collected. Further analysis by the TEM method detected asbestos at levels of less than 1% in the
indoor dust, in the apartment and in the common area.
Fibrous materials in dust found by PLM analysis: Polarized Light Microscopy identifies
asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper
(cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the
fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust
samples.