Federal Register / Vol. 52, No. 83 / Thursday, April 30, 1987 / Proposed Rules 15861

amphiboles can be identified by SAED 0.5-1.5 degrees. The measurements can gold rings are unnecessary on zone-axis analysis. be made by several methods; manually SAED patterns. Amosite. The nearest reciprocal with a ruler, with a mechanical aid, or a 25. Determination of Camera Constant lattice section to the (100) direct lattice densitometer, etc. The patterns can be Using Gold Rings; plane in amosite is (301)* and it is also read directly on the developed negative An average camera constant using the most commonly observed section. or on an enlarged nonglossy print. multiple gold rings can be determined as Due to the presence of the thin (100) In practice, it is desirable to optimize explained below. However, in practice, twins, this section closely resembles the thickness of the gold film so that in most cases determination of the (100)*. only one or two sharp rings are obtained average camera constant is not Typical EDXA spectra from amosite on the superimposed SAED pattern. Thicker gold film would normally give necessary and thicker gold films are not fibers show mainly Si and Fe with multiple gold rings, but it will tend to desirable. The camera constant, CC, is I >. smaller amounts of Mg and Mn. Mn is mask weaker diffraction spots from the one-half the diameter, D, of the rings frequently observed as a substitutional cation in amosite. unknown fibrous particulates. Since the times the interplanar spacing, d, of the Crocidolite. Most of the commonly unknown d-spacings of most interest in ring being measured and is expressed , I observed patterns are asymmetrical and asbestos analysis are those which lie as; I cannot be indexed easily. However, they closest to the transmitted beam, multiple all show rows of spots separated by a reciprocal repeat (R) corresponding to the fiber axis (0.53 nm). CC (m.m A) = DI mm) x d(S) Tile main elements observed in 2 typical EDXA analysis are Mg, Si. Ca, and Fe. Na, which is usually present in The value of d for each ring ca.n be obtained from the JCPDS crocidolite, may not be detected in gold- coated specimens because of file. . . ' , absorption, or because of overlapping secondary peaks from the copper grid. a. Measure the diameters (two perpendicular locations of Tremolite-Actinolite. Tremolite and actinolite show a variety of SAED the gold rings in mm) as precisely as possible. patterns which have very similar b. Measure as many■distinct rings as possible to minimize appearances. In actinolite some of the Mg is replaced by Fe. with the result systematic errors. that interplanar d-spacings of actinolite i are slightly larger than tremolite. In both c. Example: if the measured values in mm are Dj^,' Dj, D3, 1 tremolite and actinolite, the main 1 elemental constituents are Mg, Si, and , and Dj, these will represent, respectively, dmspacings of . Ca. Actinolite also coiitains some Fe. Anthophyllite. Even though 4.079 ,'4.079, 4.079, .4.079, and 4.079 A anthophyllite has an orthorhombic 3 2 8 11 ■ 12 crystal structure, its commonly observed patterns are similar to the monoclinic d. The camera constants will be: [1 amphiboles. Anthophyllite fibers dehydrate more easily in an electron CC, = ‘^l X 4.079 = "^l X 2.355 ~ -ZT- “ beam and are. therefore, more difficult JJ to study. . EDS elemental analysis shows the CC2 = °2 X 4^079 =■°2 X 2.04 main constituents to be Si and Mg with 2 ■“ 2“ a small amount of Fe. 24. Determination of Camera Constant CC3 = 21 X 4.079 = 21 x 1.442 and SAED Pattern Analysis; 2 2 J8 A thin film of gold is evaporated on i the specimen TEM grid to obtain zone­ CC4 = ‘’4 X 4.079 = ^4 X 1.23 axis SAED patterns superimposed with 2 2” a ring pattern from the polycrystalline 11 gold film. Since d-spacings 1 corresponding to identifiable gold rings CCc = °5 X 4.079 = '^5 .x 1.178 are known, these can be used as an 2 “ internal standard in measuring unknown 12 i; d-spacings on an SAED pattern from a i fiber. The precision of measurement is as good as the quality of the photograph (or negative) and usually the e. The camera constant for the SAED presents an example of camera-constant measurements should be in the order of pattern is the average of CCi, CCj, CC3. determination. 0.1-0.2 mm with an angular tolerance of CCi, and CCs. The following Table

NYC-WTC_000318797

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318797Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →