NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 64 pages

EPA background report, WTC air contaminants, 1987

Machine-extracted title · confidence 29%

Background report on asbestos and related contaminants for WTC environment, 1987.

NYC-WTC_000318755–000318818
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 83 / Thursday, April 30, 1987 / Proposed Rules 15857

a. Center the structure, focus, and Note.—It is not possible to inspect electron (b) Choose a magnification such that obtain a selected area electron diffraction patterns for some fibers. There are the fiber fills the STEM screen and diffraction (SAED) pattern as follows: several reasons for the absence of a position the spot over the fiber. (See Microscope Instruction Manual for recognizable diffraction pattern. These (c) Run the analysis on the EDXA more detailed instructions) include contamination of the fiber, interference from nearby particles, too small system. t (1) Select a magnification and focus. b. If the EDXA signal is weak, take a fiber, too thick a fiber, and non-suitable rhe tilt should be at 0 degrees. orientation of the fiber. Some chrysotile another spectrum, being sure that the (2) Bring the desired field of view to fibers are destroyed in the electron beam spot is still on the fiber. the screen center, making sure the resulting in patterns that fade away within c. If the EDXA is used for diffraction spot has been centered to seconds of being formed. Some patterns are confirmation, record the spectrum on a that point during the alignment very faint and can be seen only under the computer disk, with proper procedure, binocular microscope. For that reason, identification as to fiber number, disk (3) Remove the objective aperture patterns should always be examined with a number, and file number recorded on from the beam. short camera length (approximately 20 cm]

I I' (4) Insert the appropriate field limiting aperture (usually the smallest) into the and through the binoculars on the focusing screen. the count sheet. Note.—When to do EDXA: beam path. The size will depend on the c. Recording of an SAED pattern is i. Record the elemental analysis on at desired field of view. required for at least one structure of least one amphibole asbestos fiber for (5) Obtain the sharpest field limiting each classification. If the pattern is a which the diffraction pattern was aperture shadow. - . ■ suspected chrysotile, take a photograph recorded. (6) Confirm that the desired field of of the diffraction pattern at 0 degrees ii. No background spectrum or view is in the field Umiting aperture. tilt. If the structure is suspected to be constant acquisition time is required (7) Overfocus the condenser to amphibole, the sample may have to be (although normally 60 seconds is used) decrease illumination. rotated to obtain a simple geometric since the shape of the spectrum (profile) (8) Obtain a diffraction pattern. array of spots. is the criterion. (9) The beam stop may be used to (1) Change the camera length so the iii. Compare spectrum profiles with cover the central bright spot to protect photographed area of the screen is filled profiles obtained from asbestos the screen. by the diffraction pattern.' standards. The closest match identifies (10) Check the pattern on the tilted (2) Record the following information and categorizes the structure. screen through the binoculars. Use a for the photograph: iv. Use the following guidelines to . . camera length (C.L.) of approximately 20 (a) On the count sheet: Record the mm (short camera length). determine when to do EDXA, after negative number (see Note below) under having already done SAED and visually b. From a visual examination of the the SAED column. electron diffraction pattern, obtained interpreting that pattern: (b) On the negative recording log, A. For identifying and categorizing the with a short camera length of record, i. Date. approximately 20 mm depending on the amphibole structure, analyze ALL ii. Negative number (see Note below). confirmed amphiboles by the EDXA. instrument, through the binoculars on iii. kV=80-120 kV. the small screen, classify the observed B. For identifying and categorizing the iv. Magnification not applicable for structure as belonging to one of the ambiguous structure, analyze ALL by diffraction. following categories by comparing it to the EDXA. V. Initials of Operator. . known patterns. 13. Record the following on the count vi. Sample number, grid number, field (1) Chrysotile: The chrysotile asbestos number, and fiber number. sheet: pattern has characteristic streaks on the vii. Tilt used picture; 0 degrees for a. Field: List field number. layer lines other than the central line chrysotile. b. Fiber: t and some streaking also on the central (1) If no fibers are found in the field, viii. Seconds of Exposure. line. There are spots of normal ix. Camera Length (CL). • record "NFD." sharpness on the central layer line and d. Return the stage to 0 degrees tilt (2) If fibers, bundles, clusters, and/or on alternate lines (2nd. 4th, etc.) The when finished. matrices are found, then list them in repeat distance between layer lines is e. Develop the film. Compare the consecutive numerical order, starting 0.53 nm and the center doublet is at 7.3 pattern with standard reference patterns over with each field. nm. The pattern should display (002), and record the results of the verification. c. Length: Record length category of (110), (130) diffraction maxima; 12. X-ray Analysis (EDXA) (Required asbestos fibers that were examined. distances and geometry should match a . if the number of NA or amphiboles d. Fiber Type: Positive identification chrysotile pattern and be measured exceed 70 fiber per mm^): of asbestos fibers is required by the semiquantilively. a. Examine each fiber for which method. At least one diffraction pattern

s (2) Amphibole Group (includes elemental analysis is necessary (see of each fiber type on the sample must be amosite, crocidolite, anthophyllite, Section lie) with EDXA system as recorded and compared with a standard tremolite, and actinolite); Amphibole follows, after ascertaining that the stage diffraction pattern. Use the following asbestos fiber patterns show layer lines is at 0 degrees tilt. designations. To take into account the I formed by very closely spaced dots, and (1) In the TEM mode: wide variation in operator skills and the repeat distance between layer lines (a) Choose a magnification such that equipment and also to assist in the is also about 0.53 nm. Streaking in layer the fiber fills the “window” area. interpretation of fibers counts, fiber lines is occasionally present due to (b) Reduce the spot size and stigmate identifications shall be reported crystal structure defects. so that the beam overlaps the fiber. according to a defined set of codes (3) Ambiguous (incomplete spot (c) Run the analysis on the EDXA which are shown in Table III. These patterns). system. codes allow those using the data to (4) N, if there is no pattern present. (2) In the STEM mode (See the TEM determine the basis on which a fiber (This should be recorded under the Instruction Booklet for details): was identified and how certain the SAED column.) (a) Get the STEM image. identification is for the fiber. For each

NYC-WTC_000318793

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318793Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →