NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Background study draft on asbestos in schools related to WTC, March 2003.
NYC-WTC_000318678–000318754OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
41896 Federal Register / Vol, 52, No. 210 / Friday, October 30, 1987 / Roles and Regulations
seams of the bag or holes punched removed from the work area to be and securely sealed with duct tape or through the bag by a razor knife or a disposed of properly. equivalent. This plastic covering will piece of wire mesh. Minienclosures. In some instances, prevent asbestos fibers from becoming 3. The removed asbestos material such as removal of asbestos from a airborne as a result of the vibration from the pipe or other surface that has small ventilation system or from a short created by the power saws used to.cut fallen into the enclosed bag must be length of duct, a glove bag may not be the pipe. If possible, the pipes should be thoroughly wetted with a wetting agent either large enough or of the proper cut at locations that are not insulated to (applied with an airless sprayer through shape to enclose the work area. In such avoid disturbing the asbestos. If a pipe the precut port provided in most gloves cases, a minienclosura can be built is completely insulated with asbestos bags or applied through a small hole in around the area where small-scale, containing materials, small sections the bag). short-duration asbestos maintenance or should be stripped using the glove-bag 4. Once the asbestos material has renovation work is to be performed. method described above before the pipe been thoroughly wetted, it can be Such enclosures should be constructed is cut at the stripped sections. • removed from the pipe, beam, or other of &-mil-thick polyethylene plastic Enclosure. The decision to enclose surface. The choice of tool to use to sheeting and can be small enough to rather than remove asbestos-containing remove the asbestos-containing material restrict entry to the asbestos work area material from an area depends on the depends on the type of material to be to one worker. building owner’s preference, i.e., for removed. Asbestos-containing materials For example, a minienclosure can be removal or containment. Owners are generally covered with painted built in a small utility closet when consider such factors as cost canvas and/or wire mesh. Painted asbestos-containing duct covering is to effectiveness, the physical configuration canvas can be cut with a razor knife and be removed. The enclosure is of the work area, and the amount of peeled away from the asbestos constructed by: traffic in the arsa when determining containing material underneath. Once 1. Affixing plastic sheeting to the which abatement method to use. the canvas has been peeled away, the walls with spray adhesive and tape. 2. Covering the floor with plastic and If the owner chooses to enclose the . asbestos-containing material structure rather than to remove the underneath may be dry, in which case it sealing the plastic covering the floor to the plastic on the walls. asbestos-containing material insulating should be resprayed with a wetting it, a solid structure (airtight walls and 3. Sealing any penetrations such as agent to ensure that it generates as little ceilings) must be built around the pipes or electrical conducts with tape. dust as possible when removed. If the 4. Constructing a small change room asbestos covered pipe or structure to asbestos-containing material is covered (approximately 3 feet square) made of 6- prevent the release of asbestos- with wire mesh, the mesh should be cut mil-thick polyethylene plastic supported containing materials into the area with nips, tin snips, or other appropriate by 2-inch by 4-inch lumber (the plastic beyond the enclosure and to prevent tool and removed. disturbing these materials by casual should be attached to the lumber A welting agent must then be used to supports with staples or spray adhesive contact during future maintenance spray any layer of dry material that is and tape). operations. exposed beneath the mesh, the surface The change room should be Such a permanent (i.e., for the life of of the stripped underlying structure, and contiguous to the minienclosure, and is the building) enclosure should be built the inside of the glove bag. necessary to allow the worker to of new construction materials and 5. After removal of the layer of vacuum off his protective coveralls and should bo impact resistant and airtight. asbestos-containing material, the pipe or remove them before leaving the work Enclosure walls should be made of surface from which asbestos has been area. While inside minienclosure, the tongue-and-groove boards, boards with removed must be thoroughly cleaned worker should wear Tyvek ‘ disposable spine joints, or gypsum boards having . with a wire brush and wet-wiped with a coveralls and use the appropriate taped seams. The underlying structure wetting agent until no traces of the HEPA-filtered dual-cartridge or more must be able to support the weight of the asbestosrcontaining material can be ’ protective respiratory protection. enclosure. (Suspended ceilings with seen. The advantages of minienclosures are laid-in panels do not provide airtight 6. Any asbestos-containing insulation that they limit the spread of asbestos enclosures and should not be used to edges that have been exposed as a contamination, reduce the potential enclose structures covered with result of the removal or maintenance exposure of bystanders and other asbestos-containing materials.) All activity must be encapsulated with workers who may be working in joints between the walls and ceiling of bridging encapsulant to ensure that the adjacent areas, and are quick and easy the enclosure should be caulked to edges do not release asbestos fibers to to install. The disadvantage of prevent the escape of asbestos fibers. the atmosphere after the glove bag has minienclosures is that they may be too During the installation of enclosures, been removed. small to contain the equipment tools that are used (such as drills or 7. When the asbestos removal and necessary to create a negative pressure rivet tools) should be equipped with encapsulation have been completed, a within the enclosure: however the HEPA-filtered vacuums. Before vacuum hose from a HEPA filtered double layer of plastic sheeting will constructing the enclosure, all electrical vacuum must be inserted into the glove serve to restrict the release of asbestos conduits, telephone lines, recessed bag through the port to remove any air fibers to the area outside the enclosure. lights, and pipes in the area to be in the bag that may contain asbestos Removal of entire structures. When enclosed should be moved to ensure that fibers. When the air has been removed pipes are insulated with asbestos- the enclosure will not have to ba re from the bag, the bag should ba containing materials, removal of the opened later for routine or emergency squeezed tightly (as close to the top as entire pipe may be more protective, maintenance. If such lights or other possible), twisted, and sealed with tape, easier, and more cost-effective than equipment cannot be moved to a new to keep the asbestos materials safely in stripping the asbestos insulation from locution for logistic reasons, or if moving the bottom of the bag. The HEPA the pipe. Before such a pipe is cut, the them will disturb the asbestos- vacuum can then be removed from the asbes! s-containing insulation must be containing materials, removal rather bag and the glove bag itself can be wrapp, d V- th 0-mil polyethylene plastic than enclosure of the asbestos
NYC-WTC_000318747
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content
NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similar indexed content
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content