41888 Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations

sheet X-ray analysis alone can be used. the fiber, i.e., whether it is fiat, rounded q. Carefully record all data as they are as sole Identification only after ZOs/mm^ or dovetailed. being collected, and check for accuracy. have been exceeded for a particular ii. Bundle. A structure composed of r. After finishing with a grid, remove it sample. three or more fibers in a parallel from the microscope, and replace it in (5) Fibers classified as amphiboles arrangement with each fiber closer than the appropriate grid hold. Sample grids must be Identified by X-ray analysis and one fiber diameter. must be stored for a minimum of 1 year electron diffraction and recorded on the iii. Cluster. A structure with fibers in a from the date of the analysis; the sample count sheet (X-ray analysis alone can random arrangement such that all fibers cassette must be retained for a minimum be used as sole identification only after are intermixed and no single fiber is of 30 days by the laboratory or returned ZOs/mm* have been exceeded for a isolated from the group. Groupings must at the client's request. particular sample.) have more than two intersections. Iv. Matrix. Fiber, or fibers with one H. Sample Analytical Sequence (8) If a diffraction pattern was recorded on film, the micrograph end free and the other end embedded in 1. Carry out visual inspection of work number must be indicated on the count or hidden by a particulate. The exposed site prior to air monitoring. sheet. fiber must meet the fiber definition.’ 2. Collect a minimum of five air V. NSD. Record NSD when no samples inside the work site and five (Z) If an electron diffraction was structures are detected in the field. attempted and an appropriate spectra is samples outside the work site. The n. After all necessary analyses of a indoor and outdoor samples shall be not observed, N should be recorded on particle structure have been completed. the count sheet taken during the’ same time period. return the goniometer stage to 0 degrees, 3. Analyze the abatement area (8) If an X-ray analysis is attempted and return the structure to its original samples according to thia protocol. The but not observed, N should be recorded location by recall of the original analysis must meet the 0.005 s/cm’ on the count sheet location. analytical sensitivity. (9) If an X-ray analysis spectrum is 0. Continue scanning until all the 4. Remaining steps in the analytical stored, the file and disk number must be structures are identified, classified and sequence are contained in Unit IV. of recorded on the count sheet. sized in the field. this Appendix. m. Classification Rules. p. Select additional fields (grid i. Fiber. A structure having a minimum openings) at low magnification; scan at I. Reporting length greater than or equal to 0.5 /xm a chosen magnification (15,000 to The following information must be and an aspect ratio (length to width) of 20,000X screen magnification); and reported to the client. See the following 5:1 or greater and substantially parallel analyze until the stopping rule becomes Table fi: sides. Note the appearance of the end of applicable. BILUMQ coot &S40-50-M

NYC-WTC_000318739

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318739Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →