NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 77 pages

Background study draft for WTC asbestos, 2003

Machine-extracted title · confidence 37%

Background study draft on asbestos in schools related to WTC, March 2003.

NYC-WTC_000318678–000318754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations 41873

h. when polycarbonate filters are aeries. Perform this calibration using e. Select an appropriate flow rate used, position the highly reflective face guidance from EPA Method 2A each equt 'o I ' greater than 1 L/min or less such that the incoming particulate is time the unit is sent to the field (See than 10 I min for 25 mm cassettes. received on this surface. Reference 6 of Unit III.L.). Larger filters may be operated at i. Seal the cassettes to prevent b. Configure the sampling system to proportionally higher flow rates. leakage around the filter edges or preclude pump vibrations from being f. Orient the cassette downward at between cassette part joints. A transmitted to the cassette by using a approximately 45 degrees from the mechanical press may be useful to sampling stand separate from the pump horizontal. achieve a reproducible leak-free seal. station and making connections with Shrink fit gel-bands may be used for this g. Maintain a log of all pertinent flexible tubing. sampling information, such as pump purpose and are available from filter manufacturers and their authorized c. Maintain continuous smooth flow identification number, calibration data, distributors. conditions by damping out any pump sample location, date, sample j. Use wrinkle-free loaded cassettes in action fluctuations if necessary. identification number, flow rates at the the sampling operation. d. Check the sampling system for beginning, middle, and end, start and 5. Pump setup. leaks with the end cap still in place and stop times, and other useful information a. Calibrate the sampling pump over the pump operating before initiating or comments. Use of a sampling log form the range of flow rates and loads sample collection. Trace and stop the is recommended. See the following anticipated for the monitoring period source of any flow indicated by the Figure 2: with this flow measuring device in flowmeter under these conditions. BILUNQ CODE SSSO-SO-M

NYC-WTC_000318726

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318726Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →