Background study draft for WTC asbestos, 2003

Machine-extracted title · confidence 37%

Background study draft on asbestos in schools related to WTC, March 2003.

NYC-WTC_000318678–000318754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations 41871

22. "S/cm’"—Structures per cubic 3. Quality control and quality c. Cassettes must be verified as centimeter. assurance steps are needed to identify "clean” prior to use in the field. If 23. “S/mm='"—Structures per square problem areas and isolate the cause of packaged filters are used for loading or millimeter. the contamination (see Reference 5 of preloaded cassettes are purchased from 24. “TEM"—Transmission electron Unit III.L). Control checks shall be the manufacturer or a distributor, the microscope. permanently recorded to document the manufacturer's name and lot number B. Sampling quality of the information produced. The should be entered on all field data sampling firm must have written quality sheets provided to the laboratory, and 1. Sampling operations must be control procedures and documents performed by qualified individuals are required to be listed on all reports which verify compliance. Independent from the laboratory. completely independent of the audits by a qualified consultant or firm abatement contractor to avoid possible d. Assemble the cassettes in a clean should be performed once a year. All facility (See definition of clean area conflict of interest (See References 1, 2, documentation of compliance should be and 5 of Unit III.L.) Special precautions retained indefinitely to provide a under Unit III.A.). should be taken to avoid contamination guarantee of quality. A summary of e. Reloading of used cassettes is not of the sample. For example, materials Sample Data Quality Objectives is permitted. that have not been prescreened for their shown in Table II of Unit II.B. f. Use sample collection Filters which asbestos background content should not are either polycarbonate having a pore 4. Sampling materials. be used: also, sample handling size of less than or equal to 0.4 |im or procedures which do not take cross a. Sample for airborne asbestos following an abatement action using mixed cellulose ester having a pore size contamination possibilities into account should not be used. commercially available cassettes. of less than or equal to 0.45 p.m. 2. Material and supply checks for b. Use either a cowling or a filter- g. Place these fillers in series with a asbestos contamination should be made retaining middle piece. Conductive backup filter with a pore size of 5.0 pm on all critical supplies, reagents, and material may reduce the potential for ■ (to serve as a diffuser) and a support procedures before their use in a particulates to adhere to the walls of the pad. See the following Figure 1; monitoring study. cowl. BILLING CODE E560-5O-M

NYC-WTC_000318724

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318724Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →