NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 77 pages

Background study draft for WTC asbestos, 2003

Machine-extracted title · confidence 37%

Background study draft on asbestos in schools related to WTC, March 2003.

NYC-WTC_000318678–000318754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

41868 Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations

i. Fiber. A structure having a minimum after 70 s/mm’ have been exceeded for ■ outside the work site. The indoor and length greater than or equal to 0.5 gm a particular sample. outdoor samples shall be taken during and an aspect ratio (length to width) of i. Fibers classified as amphiboles must the same time period. 5:1 or greater and substantially parallel be identified by X-ray analysis and 4. Remaining steps in the analytical sides. Note the appearance of the end of electron diffraction and recorded on the' sequence are contained in Unit IV of the fiber, i.e., whether it is flat, rounded count sheet. (X-ray analysis alone can this Appendix. or dovetailed. be used only after 70 s/mm’ have been exceeded for a particular sample.) H. Reporting ii. Bund/e. A structure composed of three or more fibers in a parallel j. If a diffraction pattern was recorded 1. The following information must be arrangemerit with each fiber closer than on film, record the micrograph number reported to the client for each sample one fiber diameter. on the count sheet analyzed: iii. Cluster. A structure with fibers in a k. If an electron diffraction was a. Concentration in structures per random arrangement such that all fibers attempted but no pattern was observed. square millimeter and structures per are intermixed and no single fiber is record N on the count sheet. cubic centimeter. isolated from the group. Groupings must 1. If an EDXA spectrum was attempted b. Analytical sensitivity used for the have more than two intersections. but not observed, record N on the count analysis. iv. Matrix. Fiber or fibers with one sheet. c. Number of asbestos structures. end free and the other end embedded in m. If an X-ray analysis spectrum is d. Area analyzed. or hidden by a particulate. The exposed stored, record the file and disk number e. Volume of air sampled (which must fiber must meet the fiber definition. on the count sheet. be initially supplied to lab by client). 10. Classification Rules. f. Copy of the count sheet must be b. Separate categories will be Included with the report. maintained for fibers less than 5 p.m and a. Fiber. A structure having a minimum length greater than or equal to g. Signature of laboratory official to for fibers equal to or greater than 5 p.m indicate that the laboratory met in length. , ' 0.5 ;im and an aspect ratio (length to width) of 5:1 or greater and substantially specifications of the method. c. Record NSD when.no structures are parallel sides. Note the appearance of h. Report form must contain official delected in the field. ' - the end of the fiber, i.e.. whether it is laboratory identification (e.g., d. Visual identification of electron . flat, rounded or dovetailed. letterhead). diffraction (ED) patterns is required for b. Bundle. A structure composed of i. Type of asbestos. each asbestos structure counted which three or more fibers in a parallel would cause the analysis to exceed the I. Quality Control/Quality Assurance arrangement with each fiber closer than Procedures (Data Quality Indicators) 70 s/mm’ concentration. (Generally this one fiber diameter. means the first four fibers identified as c. Cluster. A structure with fibers in a Monitoring the environment for asbestos must exhibit an identifiable random arrangement such that all fibers airborne asbestos requires the use of diffraction pattern for chrysotile or are intermixed and no single fiber is sensitive sampling and analysis amphibole.) isolated from the group. Groupings must procedures. Because the test is sensitive. e. The micrograph number of the have more than two intersections. it may be influenced by a variety of recorded diffraction patterns must be d. Matrix. Fiber or fibers with one end factors. These include the supplies used reported to the client and maintained in free and the other end embedded in or in the sampling operation, the the laboratory’s quality assurance . hidden by a particulate. The exposed performance of the sampling, the records. In the event that examination of fiber must meet the fiber definition. preparation of the grid from the filter the pattern by a qualified individual 11. After finishing with a grid, remove and the actual examination of this grid indicates that the pattern has been it from the microscope, and replace it in in the microscope. Each of these unit misidentified visually, the client shall be the appropriate grid holder. Sample operations must produce a product of contacted. grids must be stored for a minimum of 1 defined quality if the analytical result is f. Energy Dispersive X-ray Analysis year from the date of the analysis: the to be a reliable and meaningful test (EDXA) is required of all amphiboles sample cassette must be retained for a result. Accordingly, a series of control which would cause the analysis results minimum of 30 days by the laboratory or checks and reference standards are to to exceed the 70 s/mm’ concentration. returned at the client's request. be performed along with the sample (Generally speaking, the.first 4 analysis as indicators that the materials amphiboles would require EDXA.) G. Sample Analytical Sequence used are adequate and the operations g. If the number of fibers in the 1. Under the present sampling are within acceptable limits. In this way. nonasbestos class would cause the. requirements a minimum of 13 samples the quality of the data is defined and the analysis to exceed the 70 s/mm* is to be collected for the clearance results are of known value. These concentration, the fact that they are not testing of an abatement site. These checks and tests also provide timely and asbestos must be confirmed by EDXA or include five abatement area samples. specific warning of any problems which measurement of a zone axis diffraction five ambient samples, two field blanks. might develop within the sampling and pattern. and one sealed blank. analysis operations. A description of h. Fibers classified as chrysotile must 2. Carry out visual inspection of work these quality control/quality assurance be Identified by diffraction or X-ray site prior to air monitoring. procedures is summarized in the analysis and recorded on a count sheet. 3. Collect a minimum of 5 air samples following Table III: X-ray analysis alone can be used only inside the work site and 5 samples BILUNO CODE «56O-5O-M

NYC-WTC_000318721

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318721Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →