Crystaline Building # Sample Type Method or Location Quartz Christobalite Tridymite Calcite Port/Lime Gypsum Mica Halit' 4 Air PM100 Detect ND NA Detect Detect Detect Detect Detei 4 Air PM10 Detect ND NA Detect Detect Detect ND Detei 4 Air PM4 Detect ND NA Detect Detect Detect Detect Detei 4 Air PM2.5 NS NS NS NS NS NS NS NS 4 Settled Dust Common Area ND ND ND 1.2 0.4 8.2 ND ND 4 Settled Dust Outdoor NS NS NS NS NS NS NS NS 4 Settled Dust Residence 1 0.2 ND ND 0.06 0.7 1.4 ND ND 4 Settled Dust Residence 2 13.8 ND ND 5.2 1.6 9.4 ND 0.1

5 Air PM100 ND ND NA Detect Detect Detect ND Detei 5 Air PM10 ND ND NA ND ND Detect ND ND 5 Air PM4 ND ND NA ND ND Detect ND ND 5 Air PM2.5 NS NS NS NS NS NS NS NS 5 Settled Dust* Common Area NS NS NS NS NS NS NS NS 5 Settled Dust* Outdoor 22.5 ND ND 8.4 ND ND ND ND 5 Settled Dust* Residence 1 2.1 ND ND ND ND 8.6 ND ND 5 Settled Dust* Residence 2 11.3 ND ND 3.5 0.5 2.2 ND ND

6 Air PM100 ND ND NA ND ND ND ND ND 6 Air PM10 ND ND NA ND ND ND ND ND 6 Air PM4 ND ND NA ND ND ND ND ND 6 Air PM2.5 NS NS NS NS NS NS NS NS 6 Settled Dust Common Area 16.9 ND ND 10.4 3.3 19.6 0.6 ND 6 Settled Dust Outdoor NS NS NS NS NS NS NS NS 6 Settled Dust Residence 1 26.5 ND ND 16.6 7.8 13.2 ND ND 6 Settled Dust Residence 2 23.6 ND ND 15.1 3.8 4.4 0.03 ND

7 Air PM1O0 ND ND NA Detect Detect Detect ND ND 7 Air PM10 ND ND NA ND ND Detect ND ND 7 Air PM4 ND ND NA ND ND Detect ND ND 7 Air PM2.5 NS NS NS NS NS NS NS NS 7 Settled Dust Common Area 10.5 ND ND 7.7 3.2 14.5 0.09 0.04 7 Settled Dust Outdoor 13.7 ND ND 6.6 1.3 12.4 ND 0.1 7 Settled Dust Residence 1 14.4 ND ND 12.5 2.1 1.9 ND ND /Settled Dust Residence 2 21.1 ND ND 15.9 3.4 3.5 ND O.OS 7 Settled Dust Residence 2-Co 17.6 ND ND 9.4 1.3 2.2 ND ND

CITY_21MC100_012170307

NYC-WTC_000318606

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318606Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →