NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

PCB wipe sampling GEI procedure

Machine-extracted title · confidence 46%

GEI describes PCB wipe sampling identification and custody procedures for surfaces.

NYC-WTC_000317868–000317870
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

GEI 2.19 - Collection Of PCB Wipe Samples SectionZOO-SpillResponseandCleanup

• If no sampling grid has been provided for sampliing of non post clean up PCB rwipes, draw a | sketch of the area, and indicate on the sketch where the wipe samples will be collected. Include the sample identification numbers on the sketch. • Thoroughly wet one filter paper, gauze pad, or piece of glass wool of known size with pesticide grade hexane. • Measure a 10 centimeters by 10 centimeters (100 cm^) area using a template or a measuring device. • Wipe the entire area inside the measured area with the wetted material. Wipe in parallel strokes from top to bottom twice and then from left to right twice.

It is important that the wipe sampling be performed quickly before the hexane evaporates.

• Without allowing the wipe to contact any other surfaces, carefully fold the filter paper, gauze pad, or piece of glass wool in half with the exposed side in, then fold it over again. • Place the wipe sample in an appropriate glass sample jar, and mark the sample number on the sample jar label. • Collect blank samples by thoroughly wetting the same material used for sampling i.e., one filter paper, gauze pad, or piece of glass wool of known size with pesticide grade hexane and place into an appropriate sample jar. Collect at a 10% frequency (1 blank for every 10 wipe samples), with a minimum of 2 blank samples collected for each sampling activity. • Change your rubber gloves between each sample location. Manage the used gloves as hazardous PCB waste. • Forward the sample jars to EH&S ChemLab or an approved, equivalent laboratory for PCB analysis. When submitting a sample to EH&S ChemLab or an approved, equivalent laboratory for analysis, ensure that the following information is provided to EH&S ChemLab or an approved, equivalent laboratory on a properly completed Chain of Custody/Request for Analysis Form: - Date and time sampled. I - Origin/spill location (structure or equipment identification number, if any). - Equipment serial number (if applicable). - Equipment location. - Analysis requested. - Sampler's name. - Contact person’s name (and names of others who should receive a copy of the report), ID number, and telephone number. - E-mail (bulletin board) ID. ~ Required turnaround time. ~__ Account number. E^mis number if applicable.

GEI 2.19 - Collecting PCB Wipe Samples Revision No.: 2 Section 2.00 - Spill Response and Cleanup Date: 03/08/2000 Page 2 of 3 © 1998 Consolidatad Edison Co. of New York. Inc

CITY_21MC100_003049922

NYC-WTC_000317869

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317869Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →