NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
3 shared non-person entities · similarity 0.922
machine-extracted · confidence unavailable · Check page ↗GEI describes PCB wipe sampling identification and custody procedures for surfaces.
NYC-WTC_000317868–000317870OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
GEI 2.19 - Collection Of PCB Wipe Samples SectionZOO-SpillResponseandCleanup
• If no sampling grid has been provided for sampliing of non post clean up PCB rwipes, draw a | sketch of the area, and indicate on the sketch where the wipe samples will be collected. Include the sample identification numbers on the sketch. • Thoroughly wet one filter paper, gauze pad, or piece of glass wool of known size with pesticide grade hexane. • Measure a 10 centimeters by 10 centimeters (100 cm^) area using a template or a measuring device. • Wipe the entire area inside the measured area with the wetted material. Wipe in parallel strokes from top to bottom twice and then from left to right twice.
It is important that the wipe sampling be performed quickly before the hexane evaporates.
• Without allowing the wipe to contact any other surfaces, carefully fold the filter paper, gauze pad, or piece of glass wool in half with the exposed side in, then fold it over again. • Place the wipe sample in an appropriate glass sample jar, and mark the sample number on the sample jar label. • Collect blank samples by thoroughly wetting the same material used for sampling i.e., one filter paper, gauze pad, or piece of glass wool of known size with pesticide grade hexane and place into an appropriate sample jar. Collect at a 10% frequency (1 blank for every 10 wipe samples), with a minimum of 2 blank samples collected for each sampling activity. • Change your rubber gloves between each sample location. Manage the used gloves as hazardous PCB waste. • Forward the sample jars to EH&S ChemLab or an approved, equivalent laboratory for PCB analysis. When submitting a sample to EH&S ChemLab or an approved, equivalent laboratory for analysis, ensure that the following information is provided to EH&S ChemLab or an approved, equivalent laboratory on a properly completed Chain of Custody/Request for Analysis Form: - Date and time sampled. I - Origin/spill location (structure or equipment identification number, if any). - Equipment serial number (if applicable). - Equipment location. - Analysis requested. - Sampler's name. - Contact person’s name (and names of others who should receive a copy of the report), ID number, and telephone number. - E-mail (bulletin board) ID. ~ Required turnaround time. ~__ Account number. E^mis number if applicable.
GEI 2.19 - Collecting PCB Wipe Samples Revision No.: 2 Section 2.00 - Spill Response and Cleanup Date: 03/08/2000 Page 2 of 3 © 1998 Consolidatad Edison Co. of New York. Inc
CITY_21MC100_003049922
NYC-WTC_000317869
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
3 shared non-person entities · similarity 0.922
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317871
GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
2 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
1 shared non-person entities · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208073
ATC Associates report on polychlorinated biphenyls analysis from wipe samples collected at P.S. 89M in February 2002.
2 shared non-person entities · 1 shared topics · similarity 0.909
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351946
ATC March 6, 2002 memo detailing PCB wipe sample results for BOE site.
2 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375664
Results of PCB wipe samples collected at PS 150M in Feb 2002.
2 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314181
Wipe samples for PCBs at P.S. 234M; PCB analysis results; April 7, 2002.
2 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382359
ATC wipe sample report for PCBs at P.S. 234M, March 2002.
2 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404265
ATC report of wipe samples for PCBs at P.S. 89M, BOE site evaluation.
2 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351925
ATC report of PCB wipe samples collected at P.S. 89M; BOE investigation following recommendations.
2 shared non-person entities · 1 shared topics · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000218487
Laboratory report detailing polychlorinated biphenyl (PCB) results from wipe samples collected at P.S. 234M on February 14, 2002.
2 shared non-person entities · 1 shared topics · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404427
ATC wipe sample PCB results for BOE site, March–April 2002.
2 shared non-person entities · 1 shared topics · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000100879
Permit document detailing the installation of a heavy-duty shed and facade repairs at 114 Liberty Street in May 2002.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362721
Draft scope of work for asbestos cleaning and monitoring across 11 stories at 114 Liberty Street.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390024
Chain of custody document for asbestos-related sampling at 115 West Broadway project.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163449
Chain of custody form dated August 22, 2002, documenting transfer of samples or materials between DEP personnel.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282507
Draft scope detailing on-site air monitoring and clearance sampling requirements.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155149
Correspondence confirming cleaning scope and bid process for 114 Liberty Street.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similar indexed content
NYC-WTC_000317871
GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
Similar indexed content
NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
Similar indexed content
NYC-WTC_000208073
ATC Associates report on polychlorinated biphenyls analysis from wipe samples collected at P.S. 89M in February 2002.
Similar indexed content
NYC-WTC_000351946
ATC March 6, 2002 memo detailing PCB wipe sample results for BOE site.
Similar indexed content