NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

PCDD/PCDF levels, ATC client, Oct 2002

Machine-extracted title · confidence 28%

Lab report for PCDD/PCDF levels with 17 pages prepared for ATC, Oct 2002.

NYC-WTC_000317124–000317136
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^ace Analytical" Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF analyses; DATE: October 17, 2002

PAGE: 2 REPORT NO: 02-1061865

DISCUSSION (Cont.)

It should be noted that two of the samples (DX3 and DX4) were extracted beyond the 30 day recommended hold time described in the method. Per method direction, the results should be considered minimum levels. It should be emphasized that the hold times are recognized as uncertain by the method and are considered recommendations. (Per Section 6.4 of Method 8290., hold times of up to 1 year may apply.) This is similar to Method 1613, a comparable dioxin method, which recognizes a one year holding time. Based on laboratory experience, it is extremely unlikely that the results would vary due to the additional time taken to complete the extraction of the sample material.

The response factor for the labeled OCDD internal standard in two end of shift calibration standards were outside the target range for this method. The response factors from the beginning and end calibrations were averaged to provide an accurate value for this isomer, as described in the method. The affected points are flagged "*" on the data summary sheets.

Laboratory spike samples were also prepared with the sample batch by extracting clean wipes that had been fortified with native standard materials. The results, found at the end of Appendix B, show that the spiked native compounds were generally recovered at 84-126% with relative percent differences of 0.0-21.1%. It should be noted that one native isomer was recovered above the target range for this method and is flagged "P" on the data summary sheet. The related RPD is also elevated for this isomer.

REMARKS

The sample extracts will be retained for a period of 30 days from the date of this report and then discarded unless other arrangements are made. The raw mass spectral data will be archived on magnetic tape for a period of not less than one year. Questions regarding the data contained in this report may be directed to the authors at the numbers provided below.

Pace Analytical Services, Inc.

Unze (j^roject Manager, ins (612) 607-6383

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

/nebci CITY_21MC100_003034191

NYC-WTC_000317127

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317127Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

PCDD/PCDF analyses, ATC, Oct 2002

NYC-WTC_000317150

Chemical analyses report for PCP/PCDFs on four samples submitted by ATC Associates, Oct 2002.

Similar indexed content

Compare copies and versions →