August 30, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Mercury Vapor
DeSoto School (P.S. 130M)
ATC Project No. 15-19125-0345
Dear Mr. Ori an:
ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air sampling for
mercury vapor conducted on August 26, 2002, at the referenced school. The New' York City
Department of Education (DOE) requested this sampling prior to the resumption of classes to
verify that acceptable indoor air quality is being maintained.
Scope of Work
ATC collected three (3) samples for mercury vapor using Caruhte® (Hydrar) tubes connected to
battery-pow'ered sampling pumps calibrated to collect 0.2 liters of air per minute. Samples were
collected for ten (10) hours. Two (2) samples were collected outdoors and one (1) was collected
indoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene
Association-accredited laboratory in Reading, PA. One blank tube was also submitted. Analysis
was performed by means of a mercury analyzer according to NIOSH Method 6009. A copy of
the analytical laboratory report is attached.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City
office, collected the samples consistent with accepted industrial hygiene sampling practices. The
results represent the conditions on the day the samples were collected.
The sampling locations were: the 1” floor Main Lobby, 4* Floor Hallway by Stair C and 5*'’ Floor
Hallway by Stair B.
Results
Mercury was detected in these samples at levels that were indistinguishable from those detected
in the blanks.
The established regulatory value for mercury (0.1mg m''l is intended for industrial workplace
exposures and is not generally applicable to office/school sehings. There are no standards for
mercury in indoor air in non-industrial situations. The EPA has no standard or guideline for
mercury vapor in ambient air.