NYC 9/11 Public Portal Document
1“ -
roc.
&
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
PSC
SEimCES ■EPAAJVLAP 101262-0 •NfDOHMEtAC 10303 •MJ DEP PAC20
•AIHAACCREDITATION NO 1OM39 • PA DEP 06-353 •CTOPH PH-0238
•NCDENR538
Analytical Results
for
ATC rlssociates
WorkOrder: R02O80824
Client Reference: 19125-0341
Analyte Concentration Limit of T est Date .Aitalyztd
Detection Method /Analyst
(ug) (mg/nfi’) (ppm) (UE)
Client ID: ATC-0823-2M-VOC4 Lab (D: -04A Date Sampled; 8/23/02 Matrix: Chui coal .Air \ ol.(L): \ A
1,1,1-Trichloroethane <20 20 OSHA 7 C8/2S'20C‘2
1,2-Dichloroethane <20 20 OSHA 7 08/25/2002
A Hydrocarbons, Total <20 20 OSHA 7 08/28/2002 JOS
Acetone <20 20 OSHA 7 Q3/2S/2002
B Hydrocarbons, Total <20 20 OSHA 7 08/28/2002 JL3
Benzene <20 20 OSHA 7 00/28/2002 JLS
Chlorobenzene <20 20 OSHA 7 08/28/2002 JLS
Chloroform <20 20 OSHA 7 08/29/2002 J
Ethylbenzene <20 20 OSHA 7 08/28/2002 JLS
Hexane <20 20 OSHA 7 08/28/2002 JLS
Isopropylbenzene <20 20 OSHA 7 08/28/2002 J-S
Methylene Chloride <20 20 OSHA 7 08/28/2002 JLS
Pentane <20 20 OSHA 7 08/28/2002 JLS
Styrene <20 20 OSHA 7 08/28/2002 JLS
Tetrachloroethene <20 20 OSHA 7 08/28/2002 JLS
Toluene <20 20 OSHA 7 08/28/2002 JuS
O'richloroethene <20 20 OSHA 7 08/28/2002 JI S
Xylenes, Total <20 20 OSHA 7 08/28/2002 JLS
(a) Analysis indicates possible breakthrough; back section result is greater than % of the from section result.
General Notes:
<: Less than the indicated limit of detection (LOD).
Information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
Page 4 ol ■!
CITY_21MC100_003033862
NYC-WTC_000316878
OCR can misread numbers and units. Confirm readings against the page image before using them.