Mr. Bernard P. Orlan September 16, 2002
Air Sampling for Metals Page 2
Beniamin Altman School ("P.S. 42M) ATC Project No. 15-19125-0342
The established regulatory values for metals are intended for industrial workplace
exposures and are not generally applicable to office/school settings. There are no
standards for these metals in indoor air in non-industrial situations.
Results
Chromium was detec ed in all of the samples obtained (including the blank). Copper was
also detected in two samples and blank Blank-correcting the samples lowers Cr and
Copper concentrations to below the limits of detection for the analyses. Aluminum and
Iron were detected only in the Main Lobby sample and not detected in the blanks.
The Environmental Protection Agency (EPA) has set a screening level for hexavalent
chromium in air of (>.6 ug/m\ this assumes a continuous exposure for one year. The
samples here were analyzed for total chromium (trivalent and hexavalent). The
concentrations are well below the EPA level.
The EPA has set no screening levels for Al, Cu or Iron in ambient air. I
ATC appreciates the opportunity to provide this indoor air quality service to the DOE.
Please call me at (212) 353-8280 extension 298 if you have any questions.