NYC-WTC_000351429
ATC report of May 23–24, 2002 results for respirable particulates at NYC BOE locations.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Real-time respirable particulates monitoring across NYC locations, May 28, 2002.
NYC-WTC_000315935–000315936OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 28, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314 TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* PARAMETER TARGET LEVEL AGENCY Respirable 65 micrograms per cubic Particulates meter of air (pg/m3) 24 hour USEPA NPAAQS (PM2.5) average Respirable USEPA recommendation Particulates 40 (j,g/m3 24 hour average for children/sensitive (PM2.5) I individuals USEPA = United States Environmental Protection Agency NP/\AQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates measurements* were collected from twenty-nine (29) school locations in Manhattan, ranging from West 11“’ Street to East 33'“ Street. The measurements were made from 5:51 A.M. to 4:31 P.M. The lAQ field report forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 66 pg/m3 to 98 pg/m3 with an average of 86 pg/m-L The indoor concentrations ranged from 21 pg/m3 to 71 pg/m3 with an average of 56 pg/mP Seven (7) of the indoor and all of the outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Twenty-eight (28) of the indoor and all of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m3.
These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.
CONCLUSION Based on our measurements, seven (7) of the indoor and all of the outdoor readings were above the NPAAQS of 65 qg/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Twenty eight (28) of the indoor and all of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m-b
It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.
Sincerely, ATC^SSOCIATES INC. Reviewed by:
A^jS^lJaval, . James R. Cohn, CIH, CSP Senior Profe/t Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_006740077
NYC-WTC_000315936
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000351429
ATC report of May 23–24, 2002 results for respirable particulates at NYC BOE locations.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351435
ATC monitoring results for May 29, 2002 at multiple NYC BOE locations.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315937
Real-time respirable particulates monitoring across BOE sites, May 29, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315927
Real-time respirable particulates monitoring at BOE sites, May 17, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315970
Real-time monitoring of respirable particulates conducted June 10, 2002 for NYC BOE.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208006
Letter reporting real-time air monitoring results for respirable particulates at lower Manhattan schools on May 6, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315925
Real-time respirable particulates monitoring across NYC locations, May 16, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351423
ATC monitoring results for respirable particulates at NYC BOE sites (May 20, 2002).
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315980
Results of real-time respirable particulate monitoring at BOE sites on June 17-18, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351449
ATC reports real-time respirable particulates monitoring conducted Jun 10, 2002 for NYC Board of Education.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315917
Real-time respirable particulates monitoring across several locations, May 10, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315978
Real-time air monitoring of respirable particulates conducted June 14, 2002, for NYC BOE.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000316000
Agency address notice for BOE site air monitoring; June 26, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351435
ATC monitoring results for May 29, 2002 at multiple NYC BOE locations.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351429
ATC report of May 23–24, 2002 results for respirable particulates at NYC BOE locations.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315970
Real-time monitoring of respirable particulates conducted June 10, 2002 for NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315937
Real-time respirable particulates monitoring across BOE sites, May 29, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315996
Real-time air monitoring results for June 21, 2002 at NYC BOE locations.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000351429
ATC report of May 23–24, 2002 results for respirable particulates at NYC BOE locations.
Similar indexed content
NYC-WTC_000351435
ATC monitoring results for May 29, 2002 at multiple NYC BOE locations.
Similar indexed content
NYC-WTC_000315937
Real-time respirable particulates monitoring across BOE sites, May 29, 2002.
Similar indexed content
NYC-WTC_000315927
Real-time respirable particulates monitoring at BOE sites, May 17, 2002.
Similar indexed content
NYC-WTC_000315970
Real-time monitoring of respirable particulates conducted June 10, 2002 for NYC BOE.
Similar indexed content