NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

ATC air monitoring report, NYC BOE

Machine-extracted title · confidence 28%

ATC real-time air monitoring report for NYC Board of Education schools.

NYC-WTC_000315836–000315837
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 12, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* PAH. TARGBT LEVEL |SJ I Respirable 65 micrograms per cubic Particulates meter of air (pg/m3) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 (J.g/m3 24 hour average for children/sensitive (PM2.5) I individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Twenty-nine (29) indoor and thirty-two (32) outdoor respirable particulates measurements* were collected from twenty-seven school locations in Manhattan, ranging from West 11* Street to East 25* Street. The measurements were made from 5:45 A.M. to 4:15 P.M. The lAQ field reporl: forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 24 pg/m3 to 48 pg/m3. The indoor concentrations ranged from 15 pg/m3 to 35 pg/m3. None of the indoor or outdoor readings were above the NPAAQS of 65 pg/m3. Two (2) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m3. ..

These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of the indoor or outdoor readings were above the NPAAQS of 65 pg/m3. Two (2) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m3.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES INC. Reviewed by:

iannis Efstatmou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003048048

NYC-WTC_000315837

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000315837Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196917

Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 11, 2002.

Similar indexed content

NYC-WTC_000196911

Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 9, 2002.

Similar indexed content

Compare copies and versions →