NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan April 12, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
PAH. TARGBT LEVEL
|SJ I
Respirable 65 micrograms per cubic
Particulates meter of air (pg/m3) 24 USEPA NPAAQS
(PM2.5) hour average
Respirable USEPA recommendation
Particulates 40 (J.g/m3 24 hour average for children/sensitive
(PM2.5) I individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Twenty-nine (29) indoor and thirty-two (32) outdoor respirable particulates
measurements* were collected from twenty-seven school locations in
Manhattan, ranging from West 11* Street to East 25* Street. The
measurements were made from 5:45 A.M. to 4:15 P.M. The lAQ field reporl:
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 24 pg/m3 to 48 pg/m3. The
indoor concentrations ranged from 15 pg/m3 to 35 pg/m3. None of the indoor
or outdoor readings were above the NPAAQS of 65 pg/m3. Two (2) of the
outdoor measurements were above the EPA recommended guideline for
children and sensitive individuals of 40 pg/m3. ..
These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, none of the indoor or outdoor readings were
above the NPAAQS of 65 pg/m3. Two (2) of the outdoor measurements were
above the EPA recommended guideline for children and sensitive individuals of
40 pg/m3.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC. Reviewed by:
iannis Efstatmou James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment