NYC-WTC_000294428
Careful IAQ measurements at PS 234M, dated March 14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗IAQ report for PS 234M dated March 14, 2002, BOE-initiated.
NYC-WTC_000314845–000314848OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 15, 2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATC Project No. 15-19125-0279
46 to 76 pg/m^ with an average of 53 pg/m^. One (1) of the outdoor PM2.5 measurement was above the NPAAQS of 65 pg/m^
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC^ncentration
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS
During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO ,CO2and TVOCs were within applicable standards and guidelines. 2. One (1) of the outdoor PM2.5 measurement was above the NPAAQS of 65 pg/m^. All nine (9) outdoor and eleven (11) indoor measurements were above the USEPA recommended PM2,5 concentration of 40 pg/m^ for sensitive individuals and children. 3. Thirty-six (36) of the measurements of relative humidity were below the ASHRAE recommended range of 30 to 60 percent for occupant comfort. 4. Thirty-one (31) of the temperature measurements were above the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions).
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.
Sincerely, A TCASSOCIA TES INC. Reviewed by:
Yiarmis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003032071
NYC-WTC_000314848
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294428
Careful IAQ measurements at PS 234M, dated March 14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314855
IAQ measurements collected March 13, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314875
IAQ measurements collected March 11, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000217747
ATC Associates letter reporting indoor air quality measurements collected at P.S. 234M on March 14, 2002, as requested by the NYC Board of Education.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314666
IAQ measurements report for PS 234M (Feb 2002).
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272279
IAQ measurements conducted at P.S. 234M for BOE program.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000381416
Indoor air quality measurements at PS 234M; March 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000189106
Letter from ATC Associates Inc. providing indoor air quality measurement results collected on March 13, 2002, at a New York City Board of Education school.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314646
ATC indoor air quality measurements report for PS 234M (Feb 2002).
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314865
IAQ measurements collected March 12, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182899
Report of indoor air quality measurements collected at PS 234M on February 25, 2002, to determine if acceptable air quality is maintained.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314801
ATC report of IAQ measurements conducted March 21, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294428
Careful IAQ measurements at PS 234M, dated March 14, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000217747
ATC Associates letter reporting indoor air quality measurements collected at P.S. 234M on March 14, 2002, as requested by the NYC Board of Education.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400206
IAQ measurements report for PS 89M, March 13, 2002, ATC.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313327
ATC report of IAQ measurements conducted at PS 89M.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326812
ATC IAQ measurements at PS 89M, March 13, 2002, for NYC BOE.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000381370
Indoor air quality measurements collected at PS 234M; BOE program, March 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000294428
Careful IAQ measurements at PS 234M, dated March 14, 2002.
Similar indexed content
NYC-WTC_000314855
IAQ measurements collected March 13, 2002 at PS 234M for BOE.
Similar indexed content
NYC-WTC_000314875
IAQ measurements collected March 11, 2002 at PS 234M for BOE.
Similar indexed content
NYC-WTC_000217747
ATC Associates letter reporting indoor air quality measurements collected at P.S. 234M on March 14, 2002, as requested by the NYC Board of Education.
Similar indexed content
NYC-WTC_000314666
IAQ measurements report for PS 234M (Feb 2002).
Similar indexed content