Letter: Air sampling for metals, July 2002

Machine-extracted title · confidence 26%

ATC letter reporting air sampling for metals at P.S. 234M; June 25, 2002.

NYC-WTC_000314175–000314176
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan July 26, 2002 Air Sampling for Metals Page 2 P.S. 234(Manhattan) ATC Project No. 15-19125-0279

Results

The metals detected were aluminum (Al), chromium (Cr), copper (Cu), iron (Fe)and nickel (Ni). Al and Cr were also detected in one blank. The other seven metals were not detected.

Blank-correcting the Cr concentrations (blank average: 0.7275 micrograms per filter) reduces them to below the limit of detection. Blank-correcting the Al concentration (blank : 1.07 micrograms per filter) reduces them to below the limit of detection. Cu was detected in the sample from the roof at 0.262 micrograms per cubic meter of air (ug/m^), Fe was detected in the sample from the main lobby at 2.06 ug/m^ and Ni was detected in the sample from 1“ floor hallway at 0.178 ug/m^.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 ug/m\ this assumes a continuous exposure for one year. These samples were analyzed for total chromium (trivalent and hexavalent). All Cr concentrations were below the EPA screening level.

The EPA has set a screening level for Ni in air of 2.0 ug/m’ (continuous exposure for one year). The Ni concentration detected in the T' floor hallway sample was below the EPA screening level.

The EPA has no standard or screening level for Al, Cu or Fe in ambient air.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Inc. Reviewed by:

Tenzin Namgyal/ James R. Cohn, CIH, CSP Industrial Hygi6riisi Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_003031148

NYC-WTC_000314176

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000314176Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →